Performance Parameters - Airo GORBEA R32 Manual De Usuario E Instalacion

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Performance Parameters

Rated working conditions of the air conditioning unit
Table 19 Working Temperature Range
Indoor side DB/WB(°C)
Outdoor side DB/WB(°C)
Maximum cooling
32/23
55/-
Maximum heating
27/-
24/18
Notes:
The operating temperature range (outdoor temperature) for cooling is -15°C ~55°C ; Heating
temperature range for the model without electric heating belt for chassis is -15°C ~ 24°C ;
Heating temperature range for the model with electric heating belt for chassis is -20°C ~24°C.