SECTION 10 |
SECTION 9 |
When the inverter is switched ON, the Green LED marked "POWER" (2, Fig 6.1a) will be
10.5 OVER-TEMPERATURE SHUT DOWN
lighted. This LED indicates that the input section of the inverter is operating normally. Under
In case of failure of the cooling fans or in the case of inadequate heat removal due to
normal operating conditions, AC output voltage will now be available at AC Socket and at
higher ambient temperatures /
the AC output terminals for hardwiring (13, Fig 6.1b). The Green indicator light on the
unit will increase. The temperature of a critical hot spot inside the inverter is monitored
GfCI will be lighted.
(Power Transformer T3), and at 90°C ± 5°C, the AC output of the inverter is shut down
S
witch on the AC load(s). The Green LED marked "POWER" (2, Fig 6.1a) normal operation
temporarily. Buzzer alarm will be sounded. The Green LED marked "POWER" (2, Fig
of the load.
6.1a) will remain lighted.
9.2 POWERING ON THE LOADS
The unit will automatically reset after the hot spot has cooled down to 65°C ± 5°C.
After the inverter is switched on, it takes a
Hence, always switch on the load(s) after a few seconds of switching on the inverter. Avoid
10.6 INTERNAL DC SIDE FUSES
switching on the inverter with the load already switched on. This may prematurely trigger
The following DC side fuses have been provided for internal protection of the DC input
the overload protection.
side. The fuses are 32V, Automotive Type Blade Fuses, Type "ATC" by Cooper Bussmann
When a load is switched on, it may require initial higher power surge to start. Hence, if mul-
or equivalent:
tiple loads are being powered, they should be switched on one by one so that the inverter is
not overloaded by the higher starting surge if all the loads are switched on at once.
PST-300S -12E: 12 pieces of 30A in parallel = 360A total
PST-300S -24E: 12 pieces of 15A in parallel = 180A total
9.3 TEMPERATURE CONTROLLED COOLING FAN
One thermostatically controlled cooling fan (18, Fig 6.1c) has been provided for forced air
10.7 REVERSE POLARITY AT THE DC INPUT TERMINALS
cooling. Temperature of a critical hot spot inside the inverter (Power Transformer T6) is
monitored to activate the fan and the over temperature shut-down. When the temperature
The Positive of the battery should be connected to the Positive DC input terminal of
of this hot spot reaches 55°C ± 3°C, the fan is switched ON. The fan will be automatically
the inverter and the Negative of the battery should be connected to the Negative DC
switched OFF once the hot spot cools down to 45°C ± 3°C. Please note that the fan may not
input terminal of the inverter. A reversal of polarity (the Positive of the battery wrongly
switch ON at low loads or if the ambient temperature is cooler. This is normal.
connected to the Negative DC input terminal of the inverter and the Negative of the
battery wrongly connected to the Positive DC input terminal of the inverter) will blow
9.4 INDICATIONS FOR NORMAL OPERATION
the external / internal DC side fuses. If the DC side fuse is blown, the inverter will be
dead. The Green LED marked "POWER" (2, Fig 6.1a) and the Green indication light on
When the inverter is operating normally and supplying AC load(s), the Green LED marked
the Gf CI will be switched OFF and there will be no AC output.
"POWER" (2, Fig 6.1a) will be lighted. Please see Section 10 "Protections" and Section 11
"Troubleshooting Guide" for symptoms of abnormal operation.
i
9.5 NO LOAD DRAW (IDLE CURRENT)
INFO
Reverse polarity connection is likely to damage the DC input circuitry. The internal fuse(s)
When the unit is switched ON, all the circuitry inside the inverter becomes alive and the
should be replaced with the same size of fuse(s) used in the unit. If the unit does not work
AC output is made available. In this condition, even when no load is being supplied (or, if a
after replacing the fuse(s), it has been permanently damaged and will require repair /
load is connected but has been switched OFF), the inverter draws a small amount of current
replacement (Please read Section 11 - "Troubleshooting Guide" for more details).
from the batteries to keep the circuitry alive and ready to deliver the required power on
!
demand. This is called the "Idle Current" or the "No Load Draw". Hence, when the load is
CAUTION!
not required to be operated, turn OFF the inverter to prevent unnecessary current drain
Damage caused by reverse polarity is not covered by warranty! When making battery
from the battery.
connections on the input side, make sure that the polarity of battery connections is correct
(Connect the Positive of the battery to the Positive terminal of the unit and the Negative of
!
the battery to the Negative terminal of the unit). If the input is connected in reverse
CAUTION!
polarity, DC fuse(s) inside the inverter / external fuse will blow and may also cause
When the inverter is switched OFF using the optional external Remote Control
permanent damage to the inverter.
RC-300, there will be a very minor current drain of up to 3mA for the 12V ver-
sion of the inverter and up to 5mA for the 24V version of the inverter. There will
be NO drain from the battery when the inverter is switched OFF as follows:
44
44 | SAMLEX AMERICA INC.
44
Operation
Protections
air exchange, the temperature inside the
time to become ready to deliver full power.
SAMLEX AMERICA INC. | 47