2 3 4 5 6 7 8 9 10 11
1
CN2
2
1
3
Flashing lamp
with flashing card
Opening
motor
Capacitor
Note1: When not used, bridge the N.C. contacts of safety in opening and/or of the photocell.
Note2: Output 24V, max 200mA.
Note3: When using the open collector output to manage an electro-lock, it must be powered by the
special relay card .
Security management: If the security opening command is busy during opening the gate recloses
immediately. The command is not active in closing
when the safety command (in closing) is busy during closing, the gate reopens. The command is not active
in opening.
If the two safeties are both active, the gate will not move and a start command will start it again. The gate will
restart in the opposite direction to the last engaged safety.
Attention: The motor comes without anti-squeezing security