ANOMALIES AND DEFECTS
The welding machine is equipped with protection measures that let you check the overall condition of the unit. In the
event of any anomaly, the machine will act immediately. The warning light will light up and the main screen will display
the relevant error code or alarm for the anomaly detected.
Num.
Description.
E01
Temperature error or Supply voltage error. The equipment stops working.
E04
Internal error. It may appear due to an out of range input voltage when starting the equipment. Consult your
technical service.
E05
Internal error. Consult your technical service.
E06
Error at the equipment's output. Verify that accessories and connections are not shorted. Consult your
technical service.
E07
The machine does not supply power or there is a short circuit at the output. Consult your technical service.
E08
Security error in the output voltage. It has detected a voltage exceeding the maximum in the output. Restart
the equipment. If it persists, consult technical service.
E10
Error of cooler's flow. It has been found that the cooling fluid doesn't circulates through the torch. Check the
connections. Check that the tubes are in good condition. Check the level of coolant. Check that the refrigerator
is enabled (see SPECIAL FEATURES section)
E11
High temperature of coolant. Wait for it to cool.
E20
Error of configuration data. Consult your technical service.
E21
Error of configuration data. The equipment data will be restored to the factory defaults and it will be operational
again.
E22
Internal data error. The equipment restores the data and will be operational.
FAULTS
In the event of that any fault may be hazardous to people, the machine and/or the environment, you must disconnect
the machine immediately and ensure that it cannot be reconnected until the problem that caused it has been solved.
Faults should only be eliminated by qualified personnel, taking into account the safety instructions of the machine.
LIST OF POSSIBLE FAULTS
SYMPTON
The front panel does not work, no
indicator is comes on and no indication
appears on the screen.
One or more of the error indicators is lit
up and/or the indication E.XX appears on
the screen.
The welding current does match the set
level.
Remote controls are not working.
No shielding gas.
SOLTER SOLDADURA S.L.
CAUSE
No power supply.
Mains cable or plug defective.
Possible overvoltage in the network.
The supply voltage is not correct.
External accessories are affecting the
machine start-up calibration.
It has a wrongly set remote analogue
control.
Incorrect
connection
accessories.
Connection
cable
pinched
crushed.
Incorrect gas connections protection.
Pinching or crushing in the gas tubes.
Check
fuses
installation.
Check the mains voltage.
Check the supply connections.
Check the supply voltage of the machine.
Check that the supply voltage is correct.
Disconnect accessories from the welding
terminals of the power unit.
Check remote control activation and
setting.
of
remote
Ensure
correct
remote accessories and power unit and
and/or
the good condition of the interconnection
cables.
Check gas connections between the
bottle and the power unit, between the
SOLUTION
or
protection
of
the
connection
between
13