Function
5. FAULT CHECKING AND REPAIR
No.
1
Not work,no light output and the
fan doesn't work
2
DMX no control
3
One of channel blocked
4
Can't be controlled by Sound
5
Horizontal synchronous belt
damaged
016-239
240-255
020-029
Fault description
Strobe from slow to fast
Open
Reset after 1 second
1. Check power connection and see if the fuse is OK
2. Check if voltage value is in the normal range
3. Check power switch and disply screen on or off
1. DMX signal light must be on, if not, to check the
connection
2. If DMX signal light is on, but no reaction to the chan-
nel, to check if the address code setting is correct?
3. If DMX signal is discontinuous, please check if CAN-
NON cable connect well?
4. Please Change to another DMX controller
5. Please Check if DMX signal cable is too close the
high-tension busbar which will damage or interrput
the signal output
1. Be sure no DMX signal received
2. Driving circuit of motor might be damaged
1. Be sure no DMX signal received
2. Please Check sound control is on and sensitivity is
on the right range
3. Please Check if mic is damaged
4. Please Check if the light is on "HOLD" situation
1. Power off
2. Unscrewing screws of outer case and open the base
case
3. Unscrewing screws which are connect base case to
nose-arm parts
4. Loose all of the connecting cables
5. Please change new synchronous belt and installed it
on the gear shaft and the motor driving wheel (Atten-
tion: the belt can't be too tight in case broken)
8
Fault Checking
| Tecshow Alfie Wash LZ
English version
6
P. 7