The SA-201/SA-201 Triple is a smoke detector set for discovery of fire in the first
EN
stage. If smoke develops, the SA-201/SA-201 Triple will give a loud beep of at
least 85dB (A). As part of the link function all the smoke alarms within range will
sound the alarm. We advice to test the smoke detectors weekly using the test button on
the detectors. Save this manual in a safe place or inside of the electricity meter cupboard.
RECOMMENDED INSTALLATION LOCATIONS FOR THE SA-201/SA-201 Triple:
•
place one alarm near each potential blockade of your exit route, so you are alerted
•
Use multiple smoke detectors to increase safety and ensure an alert before the escape
route is blocked.
•
•
Install at least one smoke detector in each room where people smoke or where
•
and heat will travel horizontally.
•
Install the detector on the ceiling. Except for rooms smaller than 1m, you should
stay at least 50 cm away from the wall and 61cm from any corner. Smoke and heat
do not gather in such corners, preventing the detector from alerting you on time.
61 cm minimum
DO NOT INSTALL IN THE FOLLOWING LOCATIONS:
•
The kitchen; Steam from cooking might give a false alarm.
•
The shower or bathroom; water damp might cause a false alarm and the moist
environment might damage the detector.
•
•
In front of a fan or nearby the exhaust of an air conditioner or heater.
•
In a ceiling nook.
•
In rooms where the temperature could reach below 0°C or beyond 40°C.
•
Do not paint or otherwise cover this smoke detector.
Pas de cette
salle
dead air space
Required
Do not use