2.5.1.4 Set the new Password
1. Once into the new password setting, the window displays "---". After that,
click the
or
2. At the time, click the
the ★ button when displaying the selected value of 100's digit. After that it
comes into 10's digit set. The setting methods of the 10's digit and 1's digit
are same with the 100's digit.
1
3. If the setting passwords are not same with each other, the window displays
Err, which means the password setting is not successfully, and return to the
work state directly.
4. If the setting passwords are same with each other, the window displays OK,
which means the password setting is successfully, and then into the work
state directly.
2.6. Temperature Calibration
NOTE: The temperature of the unit should be recalibrated every time if the
handle, heating element or soldering tip is replaced. Recommend using the191
or 192 series thermometer to measure the temperature of the tip.
1. Set the temperature at a certain value (for example: 350℃).
2. When the temperature is stable, measure the tip's temperature with a
thermometer and write down the value.
3. Press the
window displays CAL to enter the calibrating temperature mode. The
thermometer and then click ★ button to confirm it. Input the 10's digit and
1's digit as the method, after that, click ★ button. Here, the calibration
operation has been finished.
4. If temperature is successful, the window will display OK and then return to
the work state.
5. Repeat the above steps if there's any difference between the thermometer
and soldering station.
NOTE: If locked by password, it will not be able to calibrate the temperature
and it must input the right password.