7. Measure the distance between both bottom bracket edges (F)
(FIG. 9). The table below shows the appropriate distance needed.
U
n
nit
arrow edge
F
BBN1243SS
From 21-7/8"
to < 22-1/16"
F
BBN1303SS
From 27-7/8"
to < 28-1/16"
If the measured distance needs to be shortened, screw two
no. 8-32 x 1/4" machine screws, in each bottom embossed cabinet
brackets hole; this will slightly bend the bottom part of the brackets
(FIG. 10). Screw both brackets until the appropriate distance is
obtained.
PREPARE THE UNIT
NOTE: Since this document covers different unit models, some
details in the following illustrations may slightly differ from
your unit.
1. If present, remove all protective polyfilm from the unit and/or parts.
2. Remove the grease filter(s) by pulling down on tab and tilting the
filter(s) downward (FIG. 12). Set aside the filter(s).
INSTALL THE UNIT
1. Run house power cable
between service panel and
unit location. Stub out a 2-foot
length of power cable inside
the cabinet. Attach the power
cable to the unit using an
appropriate 7/8" diameter
strain relief (not included).
NOTE: The HCK44 cord
connection kit (optional) can
be used instead of the house
power cable. Refer to the
instruction packed with the
HCK44 cord connection kit.
2. Insert the unit in the cabinet,
until you feel a 'click' from both
sides of the unit, confirming
that the Ease of Install hooks
rest on the top of the cabinet
bottom sides
, or cabinet
brackets
or
(FIG. 15).
Move the unit from left to right,
NOTE: If, for any reason, the unit has to be removed
from rear to front and up to
ensure the Ease of Install
hooks are retaining the unit
inside the cabinet.
NOTE:The unit will be protruding
below the cabinetry until
tightened.
CONNECT DUCTWORK
Ducted Installation
Use 7" round metal duct to connect the discharge collar on the powerpack insert
to the ductwork above. An optional 7" round damper, model BP87Q, may be
used (purchase separately).
NOTE: Due to its design, the BP87Q 7" round damper cannot be installed
directly over the unit discharge collar; if this damper has to be installed,
it must be attached between two sections of 7" round metal duct
(FIG. 18). Use metal foil tape to make all joints secure and air tight.
CAUTION
Do not use screws to attach the BP87Q damper to the duct sections.
Non-Ducted Installation
A non-duct kit is required for this type of installation (purchase separately). To
install, follow the instructions packed with the kit. Refer to table at right to find
the appropriate non-duct kit according to the unit.
INSTALL THE FILTER(S)
Ducted Installation
Reinstall the grease filter(s).
Non-Ducted Installation
PM300SS unit only: Attach the non-ducted filter (included with
the HARKPM21 non-duct kit) to the back of the grease filter using
clips (provided with non-ducted filter). To order a new non-ducted
filter, use service part number S99010464.
BBN1243SS and BBN1303SS units only: Attach the non-
ducted filters (included with the HARKBN24 or HARKBN30 non-
duct kit) to the back of the grease filters using clips (provided with
non-ducted filters). To order new non-ducted filters, use service part
number S99010464-124 for BBN1243SS and S99010464-130
for BBN1303SS model.
MAINTENANCE
ALWAYS SWITCH OFF THE ELECTRICITY SUPPLY
BEFORE CARRYING OUT ANY OPERATIONS ON
THE APPLIANCE.
Grease Filter(s)
The grease filter(s) should be cleaned frequently. Use a warm
dishwashing detergent solution. Grease filter(s) is (are) dishwasher
safe.
Clean the filter(s) in the dishwasher using a non-phosphate detergent.
Discoloration of the filter(s) may occur if using phosphate detergents,
or as a result of local water conditions - but this will not affect filter
performance. This discoloration is not covered by the warranty. To
minimize or prevent discoloration, hand wash filter(s) using a mild
detergent.
Non-Ducted Recirculation Filter(s)
The Non-Ducted Recirculation filter(s) should be changed every 3 to
6 months. Replace more often if your cooking style generates extra
grease, such as frying and wok cooking.
w
ide edge
F
From 22-1/16"
to 22-5/16"
F
From 28-1/16"
to 28-5/16"
Screws in bottom
HD1376
embossed holes
HD1377
HD1340
from the cabinet, it is possible to disengage
HD1383
the Ease of Install hooks. To do so, while
holding and pushing on one side of the unit,
lift simultaneously the Ease of Install hooks
levers (1 and 2, grey parts in FIG. 16) in
the other side of the unit until the hooks
are retracted.
7" ROUND DUCT
SECTION,
12" MINIMUM
HD1383
LENGTH
Unit model
PM300SS
BBN1243SS
BBN1303SS
OPERATION
Blower Switch:
Turns blower on to LOW speed.
HQ0008
o
HQ0033
Turns blower OFF.
Turns blower on to HIGH speed.
HQ0008
Light Switch:
HQ0009
Turns light ON.
o
HQ0009
Turns light OFF.
HC0103
STAINLESS STEEL CLEANING
Do:
• Regularly wash with clean cloth or rag soaked with warm water
and mild soap or liquid dish detergent.
• Always clean in the direction of original polish lines.
• Always rinse well with clear water (2 or 3 times) after cleaning.
Wipe dry completely.
• You may also use a specialized household stainless steel cleaner.
Don't:
• Use any steel or stainless steel wool or any other scrapers
to remove stubborn dirt.
• Use any harsh or abrasive cleansers.
• Allow dirt to accumulate.
• Let plaster dust or any other construction residues reach the unit.
During construction/renovation, cover the unit to make sure
no dust sticks to the stainless steel surface.
Avoid when choosing a detergent:
• Any cleaners that contain bleach will attack stainless steel.
• Any products containing: chloride, fluoride, iodide, bromide
will deteriorate surfaces rapidly.
• Any combustible products used for cleaning such as acetone,
alcohol, ether, benzol, etc., are highly explosive and should
never be used close to a range.
BBN1243SS
8. There are 7 different sizes of optional fillers (sold
separately) designed to fit up to 15-in. depth
cabinets (for BBN1243SS unit: HADTBN24, for
BBN1303SS: HADTBN30). Choose the filler
that fits better to cover the back bottom edge of
F
the cabinet. Use 4 no. 6 x 1/2" truss head wood
FIG. 9
screws (included in the optional kit) to mount it
(FIG. 11).
Never use an electric screwdriver or drill
to screw the filler to the bottom edge of
cabinet; use a standard screwdriver.
F
FIG. 10
3. Disassemble the wiring compartment cover (grey part in FIG. 13)
from inside the unit by removing its retaining screw. Remove the
parts bag behind the cover. Set aside the parts bag and the cover
along with its screw.
4. Punch out one of the two knock-out holes (grey parts in FIG. 14).
FIG. 12
2
1
HD1383
HD1422
DUCTED
BP87Q
INSTALLATION
ONLY
Non-Duct kit model
HJ0252
HARKPM21
HARKBN24
HARKBN30
BBN1303SS
(
):
optional
aNd
uNitS oNly
CAUTION
3. Lift the unit until contact is made between the unit flange and cabinet.
Secure the unit to the cabinet using 4 no. 8 x 5/8" wood screws
included in parts bag (2 screws per side). Use upper or lower holes
(1, 2, 3, 4, 5 or 6) (FIG. 17).
1 2
3
4
5
6
HD1423
!
WARNING
The Ease of Install hooks TEMPORARILY hold the unit in
FIG. 15
place. The unit MUST BE secured to the cabinet using
the included 4 screws.
!
WARNING
Never use this unit as a shelf.
FIG. 16
WIRING
!
WARNING
Risk of electric shock. Electrical wiring must be done
by qualified personnel in accordance with all applicable
codes and standards. Before connecting wires,
switch power off at service panel and lock service
disconnecting means to prevent power from being
switched on accidentally.
1. Using appropriate wire nuts (not included), connect house power cable
to unit wiring: BLACK to BLACK, WHITE to both WHITE wires and
FIG. 18
GREEN or bare wire to GREEN ground screw (FIG. 19).
2 WHITE WIRES
GREEN
GROUND
SCREW
2. Reinstall the wiring compartment cover in the unit; ensuring the bottom
tabs are inserted in their embossed location. Secure in place using
its retaining screw (FIG. 20).
HE0430
CAUTION
Take care not to pinch wires while reinstalling
wiring cover.
HD1385
FIG. 11
HD1373
SCREW
FIG. 13
HD1341
KNOCK-OUTS
FIG. 14
HD1342
1
2
3
4
5
6
FIG. 17
BLACK WIRE
HOUSE