Model
Nozzle
C6PASCRG33
Burner nozzle
C6PASCTG33
1/100 MM
C6PASFLG33
Consumption
C6PASFRG33
Burner nozzle
C6PASCRTG66
1/100 MM
C6PASCTG66
C6PASFRLG66
Consumption
C6PASFLG66
Burner nozzle
C6PASCRTG99
1/100 MM
C6PASCTG99
C6PASFLG99
Consumption
C6PASFRLG99
GAS INLET PIPE
Determine whether the appliance is suitable for the type of gas used so that it complies with the instructions
on the label.
To convert to another gas type, check the match to the gas bearing type.
Connection of the appliance to the gas distribution must be made to a steel or copper tube complying with
applicable national requirements. Equipment should be checked on a regular basis: change if necessary.
The flexible connection between the plate and the gas installation of the premises must be approved
according to the standards in force. A valve or cut-off cock must be located upstream of the connection hose
to isolate the plate from the gas inlet.
After installation, check for possible leaks (use a suitable and approved leak detector).
The device has been tested by the manufacturer, the technical data of the device is stated on the label.
Liquid gas connection:
The gas pressure for the liquid connection should be 28 or 30 mbar for propane/butane and 37 mbar for
propane. It is necessary to check the technical label to assess the pressure and check the parameters of the
installed nozzle.
If the pressure is below 28mbar or above 37mbar, the device must not be connected.
Gas connection:
The pressure for the town gas connection must be 20 mbar. It is necessary to check the gas network
pressure as well as the nozzle installed on the device to avoid any damage and accidents.
If the gas pressure is lower than 18mbar or higher than 22.5mbar, the device must not be connected.
MANUAL
Ignition of the main burner and regulation of the thermal power: tab. A,B
Engage the ignition button by turning it to the left on the "flame" logo then hold the piezo pressure button until
the main burner ignites. You can see the flame in the opening of the front panel of the device.
Hold the igniter button for a few seconds until the thermocouple probe holds the flame, then release the
button. If the flame goes out, repeat the process.
12.8 kWh/kg
G30/G31
Burner
PROPAN /
BUTAN
28 - 30 mbar
4.0kW
93
4.0kW
0.546 kg/h
2 x 4.0
93
kW
2 x 4.0
1,092kg/h
kW
3 x 4.0
93
kW
3 x 4.0
1,638 kg/h
kW
12.8
12.8
kWh/kg
kWh/kg
G30/G31
G 31
PROPAN /
PROPAN
BUTAN
37 mbar
50 mbar
93
77
0.546 kg/h
0.546 kg/h
93
77
1.092 kg/h
1.092 kg/h
93
77
1,638 kg/h
1,638 kg/h
9.45
kWh/m3
G20
Junction
Natural
pipe for gas
GAS
20 mbar
135
G ½''
0.74 m³/h
---
135
G ½''
1,148
---
m³/h
135
G ½''
2.22 m³/h
---
FR
loading