Customer
Responsibilities
Before
Daily or
after
Frequently
Yearly
each use
each use
Check Safety Valve
•
Drain Tank
•
Air Filter (inspect and replace)
•
Inspect air lines and fittings for leaks
•
Air compressor
pump intake and exhaust valves
•
Unit cycles automatically
when power is on. When performing maintenance, you may
be exposed to voltage sources, compressed
air, or moving parts. Personal injuries
can occur. Before performing any maintenance or repair, disconnect power source from the compressor
and bleed off all air pressure.
To ensure efficient operation and longer life of the air compressor
outfit, a routine maintenance schedule should
be prepared and followed. The following routine maintenance schedule is geared to an outfit in a normal working
environment operating on a daily basis. If necessary, the schedule should be modified to suit the conditions
under which your compressor is used. The modifications
will depend upon the hours of operation and the work-
ing environment.
Compressor outfits in an extremely dirty and/or hostile environment will require a greater fre-
quency of all maintenance
checks.
NOTE: For the location of controls see "Discription of Operation" in the "Operation"
section of this manual.
To Check Safety Valve
If the safety valve does
not work properly, over-
pressurization may occur, causing air tank
rupture or an explosion. Before starting com-
pressor, pull the ring on the safety valve to
make sure that the safety valve operates
freely. If the valve is stuck or does not operate
smoothly, it must be replaced with the same
type of valve.
To Drain Tank
1.
Set the On/Auto/Off
lever to "OFF".
2.
Close the globe valve.
3.
Remove the air tool or accessory.
4.
Open the globe valve and allow the air to slowly
bleed from the air tank until tank pressure is
approximately
20 psi.
5.
Drain water from air tank by opening drain valve
(counter-clockwise)
on bottom of tank.
Water will condense in
the air tank. If not
drained, water will corrode and weaken the air
tank causing a risk of air tank rupture.
6.
After the water has been drained, close the drain
valve (clockwise).
The air compressor can now
be stored.
NOTE: If drain valve is plugged, release all air pres-
sure. The valve can then be removed, cleaned, then
reinstalled.
Air Filter - Inspection
and Replacement
Hot surfaces.
Risk of
burn.
Compressor heads
are exposed when filter cover is removed.
Allow compressor to cool prior to servicing.
A dirty air filter will not allow the compressor to oper-
ate at full capacity.
Keep the air filter clean at all
times.
1.
Remove the air filter cover.
_ver
I
2.
Remove the air filter and make sure it is clean.
IMPORTANT: Do not operate the compressor with
the air filter removed.
D21879
12- ENG