YEAR
WARRANTY
2. Mount the metal to be cut to the metal welding/cutting table. It should be mounted so that the cutting
debris falls to the cement floor.
3. Place the Plasma Cutter unit no closer than 2 meters from the workpiece to be cut.
4. Adjust the Knob on the Air Pressure Regulator to regulate the air supply between 0.4 and 0.5 MPA as
indicated on the Air Pressure Gauge. The air supply must be dry. It is recommended to install a moisture
filter (not included) on the compressor. Do not use an air oiler. (See Figure B.).
5. Securely place the clamping end of the Earth Clamp to a part of the workpiece or metal table that is clean
of paint, oil, or dirt. Clamp as close as possible to the workpiece without damaging the Cable during
cutting.
6. Set the desired current (15~45 Amps) for the type of metal being cut with the Potentiometer Knob. Thin
metals use low current and heavy metals use high current. (See Figure A.)
7. Turn the Power Switch OFF, then plug the Plasma Cutter's Power Cord into a dedicated, 110/220V electrical
outlet with delayed action type circuit breaker or fuse.
8. Hold the Cutting Torch firmly. WARNING! The Torch is "live" when its Trigger is pressed. Keep the Torch
away from people and flammables before touching Trigger.
9. When everything is in place for cut, press the Power Switch to its "ON" position. The GREEN "Power On"
Light will illuminate. (See Figure A.)
10. WARNING! TO PREVENT SERIOUS INJURY, point torch away from your body when squeezing trigger.
Once the Trigger is squeezed, the arc will ignite. This unit provides a pilot arc, so the Cutting Torch does
not need to contact the workpiece before the cutting arc ignites.
11. Squeeze the Trigger to energize the Cutting Torch, the YELLOW "Cutting" LED will illuminate. Make sure
not to touch anything else with the Torch except the workpiece to be cut. (See Figure A.)
12. Slowly move the Cutting Torch at a slight angle along the cutting line with the Torch tip trailing. The air
causes the molten metal to fall away from the workpiece being cut. If proper cutting is not achieved,
adjust the Potentiometer Knob to a higher level and/or increase air flow. (See Figure A.)
13. The torch is equipped with a 5 seconds safety shut-off when away from cut material.
14. To avoid nuisance shut-off, the tip of the torch shall remain in light contact with the cut material
throughout the cut (No more than 1.6mm away).
15. The torch is equipped with 20 second nozzle air cooling after torch trigger is released.
15