Install the range hood into the hood cabinet
1.
Determine and make all necessary cuts in the wall or
roof for the vent system. Install the vent system before
installing the cabinet hood insert. See the "Venting
Requirements" section.
2. Determine the location where the power supply cable will
be run through the wall.
3. Drill a 1¼" (3.2 cm) hole at this location.
4. Pull enough power supply cable through the wall to allow
for easy connection to the terminal box.
5. Remove terminal box cover and set aside.
6. Install the 8" (20.32 cm) round vent transition with damper
to top side of the range hood, using 4 - 3.5 x 9.5 mm
screws.
NOTE: Make sure the tabs located on the hood, are inside of
the transition before installing the screws.
7. Remove knockout from the top of the vent hood and
install a UL listed or CSA approved ½" (1.3 cm) strain
relief.
8. Place the hood insert near its mounting position
and run the power supply cable through the strain relief
into terminal box (enough to make connection).
9. Tighten the strain relief screws.
10. Using 2 or more people, lift the hood insert into
hood cabinet.
11. Fasten the hood insert using four 5x45 mm screws to the
hood cabinet and tighten securely.
I WARNING
EXCESSIVE WEIGHT HAZARD
USE TWO OR MORE PEOPLE TO MOVE AND INSTALL HOOD
INSERT.
FAILURE TO DO SO CAN RESULT IN BACK OR OTHER IN-
JURY.
4 mounting
screws
ELECTRICAL CONNECTION
Electrical characteristics (nominal)
Model
ESC128SS
Voltage
Current
7.6 A
Frequency
Maximum
lamp
2 x 6.5 W
wattage
8
Upper Hood
Insert Motor Housing
ESC146SS
120 V+/- 10%
7.7 A
60 Hz
4 x 6.5 W
I WARNING
ELECTRICAL SHOCK HAZARD.
I WARNING
DISCONNECT POWER BEFORE SERVICING.
REPLACE ALL PARTS AND PANELS BEFORE OPERATING.
FAILURE TO DO SO CAN RESULT IN DEATH OR
ELECTRICAL SHOCK.
1.
Disconnect power.
2. Locate terminal box inside of the hood insert.
D
A.White wires
B. Black wires
C. UL listed wire connectors
D. Green, bare or yellow/green wires
3. Use UL listed wire connectors and connect black wires
(B) together.
4. Use UL listed wire connectors and connect white wires
(A) together.
I WARNING
ELECTRICALLY GROUND BLOWER.
CONNECT GROUND WIRE TO GREEN AND YELLOW
GROUND WIRE IN TERMINAL BOX. FAILURE TO DO SO CAN
RESULT IN DEATH OR ELECTRICAL SHOCK.
5. Connect green (or bare) ground wire from home power
supply to the green/yellow ground wire (D) in terminal
box using UL listed wire connectors.
6. Install terminal box cover.
7. Check that all light bulbs are secure in their sockets.
8. Reconnect power.
E
F
A
C
B
E.Home power supply
F. UL listed or CSA approved ¹⁄2" (1.3
cm) strain relief