Instructions for installation and use

4.1. Installing sauna control

Heed Fig. 1 (page 8) und die Fig. 2 (page 9).
1. Screw in the three cross-head screws (20 mm) in accordance with Fig. 1
at a height of approx. 1.70 m to a distance of 7 mm into the sauna wall (see
detail in Fig. 2).
2. Hang the sauna control onto the upper cross-head screw with the aid of the
suspension device so that the control is positioned on the two lower screws.
3. Verify the secure fit of the sauna control.

4.2. Connecting cables

Heed Fig. 3 (page 9).
1. Place the heater sensor cable plug 3 into the connection socket for heater
sensor 1.
2. Place the heater, supply and light cable plugs 4, 5, 6 into the respective
connection sockets 9, 8, 7.
Connection socket 2 is not used 2 is not used.