Special things to note with various materials
It may not be possible to detect wooden studs or joists
through the following materials:
– Ceramic floor tiles
– Fitted carpeting with padded backing
– Wallpaper with metal fibres or metal foil
– Freshly painted, damp walls. These must have dried
for at least one week.
– In problem cases, use METAL-SCAN to localise nails
or screws in dry walls that line up vertically where
a stud is located.
8
AC-SCAN
For localising live wires directly beneath the plaster or behind
wooden panels and other non- metallic panelling. It is not
possible to detect live wires in dry walls with metal studs.
– Select AC-SCAN (button 4).
– As soon as the display switches from CAL to CAL OK,
you can move the device.
– MOVE: Move the tool slowly across the surface.
4 A