Changing modes of operation
Code C3
Fig. 70
Selecting unbalance readings in grammes or
ounces, active when the machine is switched
on
0* =
Readings in grams
1 =
Readings in ounces
The selected mode of operation can be transferred to
the permanent memory.
Code C4
Fig. 71
Electrical compensation of residual unbalance,
if any, in the clamping means
Measurement with increased precision (this mode
cannot be transferred into the permanent memory).
Compensation has to be cancelled and carried out once
again when the clamping means is exchanged.
Resetting the status to 0 cancels the compensation of
adaptor unbalance.
The compensation is cancelled by calibration, or
readjustment of the machine, by optimisation, or when
the machine is turned off.
0 =
Carry out compensation
1 =
Compensation completed
0 =
Compensation after the mesuring run switched
off again
* = Factory adjusted mode
Operation manual - geodyna 2300 - ZEEWB700B
Sélection du mode de fonctionnement
Code C3
Fig. 70
Sélection de l'affichage du balourd (grammes
ou onces) qui est active quand on branche la
machine
0* =
Affichage en grammes
1 =
Affichage en onces
Le mode de fonctionnement choisi peut être transféré à
la mémoire permanente.
Code C4
Fig. 71
Compensation électrique d'un éventuel balourd
résiduel dans le moyen de serrage
Mesure à précision élevée (ce mode ne peut pas être
enregistré dans la mémoire permanente).
La compensation doit être annulée puis effectuée à
nouveau après le changement des moyens de
serrage.
En remettant l'état à 0, la compensation du balourd
du dispositif de serrage est annulée.
La compensation est annulée par un étalonnage (à
l'usine, ou par l'opérateur), une lancée
d'optimisation, ou quand la machine est déclenchée.
0 =
Effectuer la compensation
1 =
Compensation achevée
0 =
Compensation après la lancée de mesure à
nouveau dé branchée
* = Programmé par le fabricant
79