24
•
Remove the filter cover.
•
The filter should be rinsed with water, e.g. from
a garden hose, and it can be re-installed in the
device. If the filter is discoloured or has dirt that
cannot be removed, replace it with a new one.
•
Put the cover on the filter.
•
Screw the filter to the pool wall.
Draining the water
•
Disconnect the device from the power supply.
•
Make sure that the hole in the floor on the inside
of the pool is closed.
•
Open the water outlet on the outside of the pool.
Connect one end of the hose.
•
Open the hole plug on the inside of the pool, the
water will flow out through the hose.
•
After draining all the water, activate the air
bubbles release function for about 2-3 minutes to
get rid of water from the tubes in the device.
•
When finished, disconnect the hose and close the
holes with the plugs.
Storage
•
Completely drain the pool water. Remove the
filter.
•
After draining the water, dry the pool with a dry
cloth and leave it to dry for 24 hours until it is
completely dry.
•
Release the air from the pool by opening the
outlet and air valve, then fold it into the box.
Using the repair kit
•
If the product gets torn or breaks, use the
provided repair kit.
•
Clean and dry the area of damage. Cut out the
patch.
•
Apply the adhesive to the patch, then gently
fasten it to the damaged area.
•
Smooth the surface to remove air bubbles.
3.4. CLEANING AND MAINTENANCE
a)
Before each cleaning, adjustment, replacement
of accessories and if the device is not used, it is
necessary to pull out the mains plug.
b)
Use cleaners without corrosive substances to clean
each surface.
c)
Contaminants may be deposited on the walls of the
pool. To clean them, use a mild soap and water.
d)
After cleaning the device, all parts should be dried
before reusing it.
e)
Store the unit in a dry, cool place, free from moisture
and direct exposure to sunlight.
f)
Regular inspections of the device must be carried out
in terms of its technical efficiency and any damages.
g)
Use a soft cloth for cleaning.
Problems
Cause
The display does not respond /
The safety switch is deactivated
does not switch on
The water temperature is above
116.6°F (47°C)
Air jet system not working
Overheating of the air fan motor
Problem with the filter/air and
massage jets/heater unit
Massage jet system not working
Overheating of the massage jet
motor
Problem with the filter/air and
massage jets/heater unit
Heater not working
Temperature set too low
The water temperature is still
within the tolerance range of the
temperature sensor <+/- 35.6°F
(2°C)>
Spa is not covered
The filter cartridge is dirty
Water level too low
Problem with the filter/air and
massage jets/heater unit
Dirt deposits inside the motor
block (Heating pipe with dirt. Filter
pump blocked. Plugged filter
cartridges)
Filter system not working
The filter cartridge is dirty
Water level too low
25
Solution
Perform a reset
Wait until the water temperature
has dropped below 104°F (40°C)
and press the "manual reset
button"
Wait until the motor has cooled
down, then press the bubble but-
ton to activate the function
Disconnect the power supply, wait
10 minutes before switching the
power back on
Wait until the motor has cooled
down, then press the JET button to
activate the function
Disconnect the power supply, wait
10 minutes before switching the
power back on
Set a higher temperature 68°F
-104°F (20-40°C)
Once the set water temperature
reached, the heater will stop wor-
king until the water temperature
drops 35.6°F (2°C) below the set
temperature. In this case just wait
for a few minutes and the heater
will start working automatically.
Attach the cover
Replace the filter cartridge
Top up the water
Disconnect the power supply, wait
10 minutes before switching the
power back on
Remove the filter cartridge and
flush the motor block using a water
hose by placing the water hose at
the water outlet and collecting par-
ticles of dirt at the filter connection
using a cloth bag
Replace the filter cartridge
Top up the water