GB
5.
SPECIAL FUNCTIONS
5.1 Keyboard lock Function
Use this function to prevent all change of your
settings (In a child room, public area...)
• To activate the Key lock function, press
maintained the both LESS ( ) or MORE
( ) keys.
• The logo will be displayed on the screen.
• Repeat the same procedure to unlock the
key board.
5.2 Open window function
Conditions of open window detection:
The thermostatic head detects an "Open
window" if the room temperature decreases
by 5°C or more during a 30 minutes period
(or less).
In this case, the thermostatic head follows
7.0°C setting. The function remains active
until the room temperature increases or until
any key is pressed.
As an indicator of this function running, the
logo
will blink.
Return to normal mode:
• Automatically: Room temperature increas-
es again for more than 1°C in less than
½ hour
• Manually: Press the ( ) button
Then the blinking logo
indicate the end of the detection and return to
previous setting temperature.
Special cases:
• This function doesn't work if Thermostatic
head is in OFF / Antifreeze Mode
should disappear to
5.3 Valve exercise function
This function is performed if the thermostatic
head doesn't move during 2 weeks.
This function doesn't work in OFF mode.
6.
PARAMETERS MENU
Your thermostatic head has parameters menu,
in order to enter in this menu, press and
maintain the ( ) key during 5 seconds. Then
parameters menu will appear and first param-
eter screen will be displayed: Now you can
select a parameter which must be adjusted
with the navigation LEFT (
keys, once the parameter chosen, toggle the
value with the ( ) key, modify it with LESS (
) or MORE ( ) and confirm your adjustment
with ( ) Key.
To leave the parameter menu, choose the
parameter
(menu number 21) and press
End
( ).
N° Default value & other possibilities
10 oooo Thermostatic head initialization
This menu is used for the first time you
install the thermostatic head on the heat-
er.
It helps to completely open or close the
thermostatic head and need to be done
once.
11 rF Radio configuration
Sends the radio link signal in order to
) or RIGHT ( )
37