Xylem JABSCO 35760 Serie Manual De Instrucciones página 2

Soplador de 4" para servicio continuo
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 17
Contiuous Duty 4" Blower
FEATURES
• Extended life 5,000 hour motor
• Tough reinforced thermoset plastic housing
• Mounts to any flat surface
• Slip-on inlet ducting connection
• Efficient high volume air flow
• Low-current draw
• Corrosion-resistant materials throughout
• N.M.M.A. type accepted
• Meets USCG regulation 183.410 and ISO 8846 Marine
Ignition Protection
• Complies with ISO 9097 MARINE
• Conforms with EN 60945, EN 61000-6-1, and EN 61000-6-3
Model
35760-0092
35760-0094
Model
35770-0092
35770-0094
INSTALLATION
INSTALLATIONS MUST MEET APPLICABLE SECTIONS OF TITLE
33, PART 183; SUBPART K, USCG VENTILATION REGULATIONS.
Flangemount Mounting
Mount blower on flat bulkhead surface in highest part of compart-
ment free from spray or deck wash. Cut a 3-5/8" hole in bulkhead
and secure blower with washers and No. 10 screws (NOTICE:
Tighten screws evenly to avoid flange damage). Use a suitable dis-
charge fitting so that static pressure of blower will not be affected
by change in wind direction. Route inlet ducting with as few bends
as possible to lower 1/3 of the bilge compartment where vapors
are likely to accumulate. Be sure ducting is positioned below top
of engine stringers but not so low as to become submerged in
bilge water. Locate pickup to take advantage of natural air flow.
Flexmount Mounting
Mount blower on flat bulkhead surface in highest part of com-
partment free from spray or deck wash. Blower may be rotated in
mounting bracket to facilitate the shortest route of ducting. Use a
suitable discharge fitting so that static pressure of blower will not
be affected by change in wind direction. Route inlet ducting with
as few bends as possible to lower 1/3 of the bilge compartment
where vapors are likely to accumulate. Be sure ducting is posi-
tioned below top of engine stringers but not so low as to become
submerged in bilge water. Locate pickup to take advantage of
natural air flow direction.
SPECIFICATIONS – Flangemount
Air Flow
250 CFM (7,0 m³/min)
250 CFM (7,0 m³/min)
SPECIFICATIONS – Flexmount
Air Flow
250 CFM (7,0 m³/min)
250 CFM (7,0 m³/min)
Flangemount
Voltage
Amps
12 VDC
11
24 VDC
6
Voltage
Amps
12 VDC
11
24 VDC
6
NOTICE: Blowers should be mounted away from extreme
heat (more than 130°F) to prevent distortion of blower wheel or
housing.
OPERATION: See following warning placard statement:
WARNING: Gasoline vapors can explode.
Before starting engine, operate blower for
4 minutes and check engine compartment
for gasoline vapors. Run blower below cruising speed.
THE "WARNING" PLACARD SUPPLIED WITH BLOWER MUST BE
MOUNTED ADJACENT TO ENGINE IGNITION SWITCHES (ALL LOCA-
TIONS) TO COMPLY WITH TITLE 33, PART 183; SUBPART K, USCG
VENTILATION REGULATIONS.
WIRING
Use marine grade copper wire. For lengths up to 25 feet (7,6 m)
from power source: Use 12 gauge wire for 12 volt and 14 gauge
wire for 24 volt. Use larger wire for longer lengths. Use a 10 amp
rated on-off switch in positive side of circuit (Model 44960-0002).
Circuit must be protected with a fuse. Suggested fuse sizes are
listed in the specification table.
MARINE SWITCH
LIGHTED SWITCH
2
Flexmount
Fuse Size
15
6 lb (2.72 kg)
10
6 lb (2.72 kg)
Fuse Size
15
7 lb (3.18 kg)
10
7 lb (3.18 kg)
PANELS
44960-0002
W/BOOT SPST
Weight
Weight
loading