Inserting the battery
Caution! There is a risk of explosion if the battery is replaced by an incorrect type.
1
Slide out the battery compartment cover.
2
Insert the battery, and ensure correct polarity.
3
Close the cover.
Warning! Dispose of used batteries according to the manufacturer's instructions and according to local rules and
regulations.
Enrolling the keypad to the panel
1
Enter the Installer menu and select 02: Zones/Devices.
2
Select Add new devices.
3
Press the Function button on the keypad until the LED lights yellow.
The panel displays, for example, Device enrolled K02: Prox Keypad ID No. 371-XXXX.
Alternatively, enter the device ID digits 371-XXXX, as printed on the keypad label.
The panel displays, for example, ID accepted K02: Prox Keypad ID No. 371-XXXX.
4
Optional: Navigate to choose the keypad number (for example, K04).
5
Press OK.
If the partitioning feature is enabled in the panel, the Partitions menu displays.
6
To assign the keypad to one or more partitions, press the 1, 2 or 3 buttons on the panel.
7
Press Next. The Dev settings menu displays.
8
Press OK to enter keypad configuration.
Table 2: Keypad configuration options
Option
Tampers
Supervision
Exit-Entry Beeps
Sounder volume
Button (*)
Note: For more information on enrolling a new keypad to the control panel, modifying the settings, or deleting an enrolled keypad, refer to the relevant section in
the control panel's installer guide.
4
Function
Determines if the keypad reports on both the battery cover and back tamper (all tampers), the battery cover tamper only
(battery cover), or none (disabled – default).
Determines if the control panel monitors the integrity and quality of the radio link. A missing trouble alert occurs if the keypad
misses at least one supervision signal within 5 minutes. The options are enable or disable (default).
Determines if the keypad always sounds the exit and entry beeps (on), only when the system is armed away (off @ home), or
does not sound exit-entry beeps at all (off – default).
Determines the keypad sound volume. The options are minimum, medium (default), and maximum.
Determines the use of the Function button from the following options:
Status (default): Announces the system status. Applicable only for panels with voice capabilities.
▪
Skip exit delay: Stops the exit delay time.
▪
PGM action: Activates the PGM output.
▪
Stop beeps: Causes the control panel and other devices in the system to stop beeping.
▪
Not used: No function assigned to the Function button.
▪
Figure 2: Inserting the battery
WK-241 PG2 – Installation Instructions