GRE GFH09EA-K3DNA1A/I Manual Del Propietário página 24

Idiomas disponibles

Idiomas disponibles

3) Insert the signal line to the four-pin socket on the printed circuit board of the
indoor unit.
4) Fix the signal line with the binding wire.
18 Electric Installation
Indoor Unit
Type
Model
GFH(09)EA-K3DNA1A/I
GFH(12)EA-K3DNA1A/I
Cooling
and
GFH(18)EA-K3DNA1A/I
Heating
GFH(21)EA-K3DNA1A/I
GFH(24)EA-K3DNA1A/I
Notes:
The sectional area listed above is applicable to the power cord with at most a
length of 15 meters. For the longer cord, its sectional area should be enlarged to avoid
the cord burning out caused by the over-current.
Ⅳ Rated Working Conditions
Dry bulb temp. ℃
Rated Cooling
Max. cooling
Min. cooling
Rated Heating
Max. heating
Min. heating
Table 7
Power Cord
220-240V~
50Hz
220-240V~
50Hz
220-240V~
50Hz
220-240V~
50Hz
220-240V~
50Hz
Table 8 Working Temperature Range
Indoor side state
Wet bulb temp. ℃
27
19
32
23
21
15
20
15
27
20
15
Running
Current
Input Power(W)
(A)
Indoor
Fan
Cooling
Motor
0.406
75
0.348
65
0.428
80
0.588
110
0.588
110
Dry bulb temp. ℃
35
48
18
7
24
-15
20
Unitary Duct Split
Recommended
Power Cord
(Sectional
Area× Pieces)
Heating
575
1.0×4
865
1.0×4
1080
1.0×4
1610
1.0×4
1610
1.0×4
Outdoor side stae
Wet bulb temp. ℃
24
26
6
18
-16