Keypad
Pressing it for 3 seconds activates/deactivates Stand-By mode. In this mode, regulation is paused and the
In the programming menu, this exits the parameter without saving changes, returns to previous level or exits programming.
Pressing once without holding displays the temperature of probe S2 for 2 seconds (if it is enabled).
Pressing it for 3 seconds starts/stops the defrost.
In the programming menu, this allows scrolling around the di erent levels, or, during the setting of a parameter, changing its value.
A brief press shows the ADAPTIVE mode operating alerts.
Pressing it for 3 seconds activates/deactivates continuous cycle mode.
In the programming menu, this allows scrolling around the di erent levels, or, during the setting of a parameter, changing its value.
Pressing once without holding activates/deactivates the cold room light.
Pressing it for 3 seconds accesses the condensed programming menu.
Pressing it for 6 seconds accesses the expanded programming menu.
In the programming menu, this accesses the level shown on the display or, during the setting of a parameter, accepts the new value.
Pressing once without holding displays the current e ective value of the Set Point, taking into consideration temporary
modi cations by other parameters (C10 or C12).
When an alarm is in progress, pressing once without holding mutes the acoustic alarm. Pressing for 3 seconds accesses the Set
Point setting.
Indicators
Fixed: Stand-by Mode activated. Regulation is paused.
Flashing: Controlled shutdown process for the regulation
in progress.
Fixed: Cold room door open.
Flashing: The door has been open for a greater time than
has been de ned in parameter A12.
There is an active alarm, but not an active HACCP alarm.
Fixed: HACCP alarm active.
Flashing: HACCP alarm registered and uncon rmed.
Press the
key to con rm an HACCP alarm.
Fixed: The ADAPTIVE mode is active.
Flashing: An error has been detected in the ADAPTIVE
mode.
Fixed: Evaporator fans active.
Flashing: The evaporator fans should be active but a
delay is preventing this.
STAND-BY
If the temperature regulation cannot be instantly stopped due to its con guration, a controlled stop process starts and the
icon ashes. To stop the controlled stop process and force the step to Stand-by, press the Stand-by key again for 3 seconds.
2 | AN41504517847601-000102
Fixed: The cold solenoid is active.
Flashing: The solenoid should be active but a delay or
protection is preventing this.
Fixed: Compressor active.
Flashing: The compressor should be active but a delay or
protection is preventing this.
Defrost relay active.
Continuous cycle mode active.
Cold room light active.
Alarm in progress muted.
Temperature displayed in ° Fahrenheit / ° Centigrade.
Programming mode active.
© Danfoss | Climate Solutions | 2022.08
icon is displayed.