Operating Instructions
Safety Switch TX...AS1
19
39
59
M12 plug connector,
not aligned
C
Fig. 4: Dimension drawing for TX...AS1
Hinged actuator
X‑LR‑N
Fig. 5: Minimum door radii
Insertion depth
s
Actuator
Insertion depth s
Standard
32 + 1
Overtravel
32 + 8
For M5 > 45 mm
ISO 1207 (DIN 84)
ISO 4762
(DIN 912)
M = 1.5 Nm
GN
RD
30
42
D
A
Standard
4,5
8,5
B
Auxiliary release
Locking screw
50
40
20
Hinged actuator
X‑OU‑N
13,5
30
45
10
20
+1
30
0
With escape release
Key to symbols
Guard locking ready for operation
/
Guard locking released
/
40
16
8
Door radius, min.
Actuator
Actuator X-GQ
Actuator X-WQ
Hinged actuator X-OU-N
Hinged actuator X-LR-N
21,5
[mm]
300
300
100
100