Urmet MTV300E-UP Instrucciones página 9

Receptor atenuador temporizado radio zigbee
Ocultar thumbs Ver también para MTV300E-UP:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 13
MTV300E-UP
4820408 Dimmer 300W ZigBee
All UP receivers are compatible with UP transmitters
(remote controls, wall-mounted remote controls, flush-mounted transmitters).
Installation
The module must only be installed by qualified personnel and
in a location inaccessible to the end user, in accordance with
national installation regulations.
In order to comply with safety regulations, the module
must be connected to a power line protected upstream by
a 13A circuit breaker in C elbow.
Attention:
- If the module supply line is shared with inductive loads (e.g. shutters or ferromagnetic
ballasts or transformers), the FDVDT accessory (Ref. 5454075).
- The accessory must be connected as close as possible to the module, in parallel between
phase and neutral. Without this accessory, the module's internal overvoltage protection
could be quickly destroyed.
- For a load greater than 50W or 50VA, we also recommend installing the FDVDT accessory
to limit electromagnetic interference.
General functions
Caution: before carrying out any configuration, unlock
the product with 23 short presses. Automatic lock after 6
hours.
Short press-
Functions
es (N)
20
Relay mode (no dimmer functionality)
21
Locking configurations
22
Flashing mode*
23
Unlocking configurations
24
Shutdown warning
25
Set duration in seconds
26
Set duration in minutes
27
Minimum brightness level adjustment
Reset minimum brightness level to
28
factory setting
Factory exit reset and network connection
30
cancellation
32
100% or memory mode on first press
Status memory in case of
35
missing network
9/28
ZigBee radio timer dimmer receiver
Response (no.
of flashes)
10
1
2
3
4
5
6
7
8
2
8
2
*Toggles between OFF and ON
Disconnect the power
supply to the system before
commissioning
Do not install in a
waterproof box
if the load consumes
more than 0.6 A
Layouts
Upon exiting the factory, timing is not active
Short press-
Duration (factory setting in minutes)
es (N)
11
2 minutes
12
4 minutes
13
8 minutes
xN
14
15 minutes
15
30 minutes
16
1h (60 minutes)
17
2h (120 minutes)
18
4h (240 minutes)
19
Unlimited (no timing)
All configurations are preserved in the absence of mains
voltage.
If the module is controlled by a remote control and the latter only has
this module associated with a button - in standard mode (code 1), it
is possible to configure the module from the remote control without
having access to the module's local button.
xN
Access the product page
for further information.
250m in free air space or inside a 100m² house
with perpendicular crossing of a main wall or
slab.
EN
EN
Response (no.
of flashes)
1
2
3
4
5
6
7
8
9
loading

Este manual también es adecuado para:

4820408