Stid SLA-R41-A/U04 Serie Manual De Instalación página 4

Idiomas disponibles

Idiomas disponibles

Read only & OSDP
TM
readers
The number of antennas & channels and the communication protocol are configurable with the ULTRYS application or when the reader is ordered. Please refer
to ULTRYS for more details about configuration settings.
TTL protocols (Wiegand & ISO2): refer to Spec_Protocole_Wiegand_V2.1_EN & Spec_Protocole_Clock&Data_V2.1_EN.
Serial protocols (RS232 & RS485): the structure of the frame can be configured with the ULTRYS application with the following optional parameters (in
gray):
ASCII: if this option is activated, the data will be sent in ASCII mode (data size will be doubled)
-
Padding: complete the tag data with not significant 0 to obtain the defined data size - (Channel no. + 0 padding + tag data).
-
OSDP™ protocol (RS485: 7OS): refer to ULTRYS for more details about configuration settings + refer to Spec_Protocole_7OS_OSDP_UHF-EN.pdf.
When the reader is switched on, the reader's red LED lights up. Reader initializing.
After initializing, the reader will look for a configuration tag for about 15 s, on antenna 1 (connected to RF port 1).
• If no tag detected: the antenna LED flashes "color RFON" (200ms) (blue by default) / RFOFF (200ms).
• If any tag detected: the antenna LED displays the sequence "color RFON" (blue by default) / "color DETECTION" (orange by default) for 200ms then LED OFF.
• If a configuration tag is detected: the antenna LED displays the sequence « color RFON "(blue by default) / "color DETECTION" (orange by default) for 200ms
then LED OFF, then the antenna LED gives the followings indications:
3 GREEN flashes (500ms ON; 200ms OFF): the configuration tag is taken into account.
-
3 RED flashes (500ms ON; 200ms OFF): the regulation (region) of the configuration tag does not match to the regulation of the reader.
-
3 PURPLE flashes (500ms ON; 200ms OFF): the key of the configuration tag does match to the reader key.
-
5 RED flashes (500ms ON; 200ms OFF): the model of the reader of the configuration tag does match to the model of the reader.
-
The end of the start sequence is indicated by the flashing of the reader LEDs (red and green) 3 times (500ms ON; 500ms OFF).
Power supply OK:
Power supply too low:
Temperature error:
RF error, antenna problem:
Communication:
SSCP
®
readers
When the reader is switched on, the reader's red LED lights up. Reader initializing.
After initializing:
If the reader is a RS232 reader: reader's green LED blinked 3 times.
If the reader is a RS485 reader: reader's red LED blinked 3 times.
The reader then waits for command.
More details about reader's communication are available in the protocol specification: Spec_Protocole_SSCP_UHF_ACCESS.
Power supply OK:
Power supply too low:
Communication:
© STid - 20 PA des Pradeaux FR13850 Gréasque - NI1132X01 - Page 3 sur 24 - Ed. 21/02/2024
STid reserves the right to make change without notice, for the purpose of product improvement.
SPECTRE Access UHF
Installation procedure
1 byte
1 byte + X bytes
STX
Channel number + Tag Data*
0x02
0x0y nn.....nn
fixed red LED
blinking red LED (500ms ON / 500ms OFF)
blinking red LED 5 times after all reading sequence. (RF Scan)
blinking red LED 3 times after all reading sequence. (RF Scan)
green LED
fixed red LED
blinking red LED (500ms ON / 500ms OFF)
green LED
UHF SPECTRE Access
Notice d'installation
Configuration
1 byte
1 byte
LRC
CR
0x0D
Start Sequence
Red/Green Module LED indication
Operating Mode
Red/Green Module LED indication
UHF SPECTRE Access
Manual de instalación
1 byte
1 byte
LF
ETX
0x0A
0x03
US
FR
ES
loading