Craftsman 919.167710 Manual Del Usuario página 23

Ocultar thumbs Ver también para 919.167710:
Idiomas disponibles

Idiomas disponibles

PROBLEM
CAUSE
CORRECTION
Motor will not
Extension cord is wrong
Check for proper gauge wire
run.
length or gauge,
and cord length.
Check valve stuck open.
Replace check valve.
Loose electrical connections.
Have checked by a Trained
Service Technician.
Possible defective motor.
Have checked by a Trained
Service Technician.
Paint spray on internal motor
Have checked by a Trained
3arts.
Service Technician.
Do not
operate the compressor in the
paint spray area. See flam-
mable vapor warning.
Pressure release valve on
Bleed the line by pushing the
3ressure switch has not
lever on the pressure switch to
unloaded head pressure,
the "Off" position; if the valve
does not open, replace switch.
1.
Fuse blown, circuit breaker
tripped.
2.
3.
4.
Check fuse box for blown
fuse and replace as
necessary. Reset circuit
breaker. Do not use a fuse
or circuit breaker with
higher rating than that
specified for your particu-
lar branch circuit.
Check for proper fuse.
You should use a time
delay fuse.
Check for low voltage
conditions and/or proper
extension cord.
Disconnect the other
electrical appliances from
circuit or operate the
compressor on its own
branch circuit.
Compressor is tripping
Have checked by a Trained
the Ground Fault Current
Service Technician.
interrupt (GFCI) switch.
Faulty pressure switch
Have checked by a Trained
Service Technician.
23-ENG
N022059
loading