DINUY DM TEC 008 Instrucciones De Uso página 5

Detector de movimiento de techo 360 para instalación empotrada , 1 canal / 10a
Idiomas disponibles

Idiomas disponibles

WIRING DIAGRAMS
• Installation of electric equipment must be carried out
by qualified professionals.
• Before you start making any connections, disconnect
the power supply to avoid any risk.
• When some kinds of lamps blow, they can produce a
very high current which could damage the detector.
NOTE
Once the detector is connected to power, it is necessary to
wait 2 minutes for its stabilization. During this time, the device
activates its output and does not respond to movement.
● Follow one of the following diagrams to make the connections:
- Simple installation:
230V~
50/60Hz
- Installation of 2 detectors in parallel:
230V~
50/60Hz
- Installation with a Switch for activate or deactivate manually
the movement detection:
230V~
50/60Hz
- Installation with a Switch for permanent ON:
230V~
50/60Hz
- Installation with Staircase lighting timer (MI EL3 003), with
the timing set by the Staircase timer (DP TEC 008: 6sec):
230V~
50/60Hz
- Installation with Timer (MI PLA 002) and buttons in parallel,
each one with its timing:
230V~
50/60Hz
SETTINGS AND TEST
SETTINGS
"Lux" and "Time" values can be adjusted via its control knobs.
- Lux Settings (LUX)
This setting allows to select the minimum level of natural light in
wich the detector would detect movement. In case it detects
movement and natural light is below the indicated level, the
device will not respond.
The user can set this value between 3 and 100 Lux.
If the detector is expected to work despite of surrounding
natural light, set the potentiometer in "
On the contrary, if you want the detector to work only at night
(without any natural light), set the potentiometer on "
- Time Settings (TIME)
This setting allows to select the span of time during which
lamps will remain on, after movement detection.
Timing starts whenever movement is detected.
This time can be set between 6sec and 12min.
TESTING PROCESS
● The purpose of the test procedure is to check and adjust the
coverage pattern of the motion sensor when it is connected for the
first time.
NOTE
Once it is powered, the detector needs ~2 minutes for
initialization. Then it will start operating normally.
● The red LED which is within the lens can be used as an indicator
when performing the testing process without any load. This LED
lights whenever motion is detected and stays on until the time delay
expires.
● Set the "Lux" potentometer on "
● Walk towards the coverage area. Once it detects movement, the
LED as well as the lamps will be lit for 6 seconds.
MASKING CLIPS
● There are three covers available to restrict the coverage area.
● To fix the restriction covers, the decorative frame has a slot on its
rear side, where the projection of the cover fits.
CAUTION: Dangerous voltage!
L
N
L
N
N L
L
N
L
N
L
N
N L
L
N
MI PLA 002
Load
N L
L
L
Load
L
L
N
L
L L
N L
L
L
L
L
LUX
TIME
" and "Time" in the minimum.
N L
L
L
Load
Switch
Switch
2
1
4
3
MI EL3 003
N L
L
".
L
".
loading