Installation and operating instructions
5915 | 5916 | 5917 | 5918
ixalo knob cylinder
24
5.
Signalling
Event
The user transponder will be held in front of the
cylinder but the access point has not been assigned
to a master key system
→ 3x yellow LED
Access point was successfully assigned to a master
key system using the master card
→ 5x green LED and beeping
Access point could not be assigned to a master
key system using the master card
→ 5x red LED
Access successful
→ 1x green LED and 1x short beep
Reading error or transponder is not authorised for
access
→ 2x red LED and, 2x short beep
Access point has an internal communication problem,
transponder is authorised but the cylinder is not
engaging
→ 2x green LED and 2x short beep
Access point does not have a valid time,
access point with restricted* function
→ LED flashes continuously red
Standby or daytime release active
→ LEDs are off
Low-battery alarm 1
→ release delayed by 10 s
slow beeping
Low-battery alarm 2
→ fast beeping for 20 s, release does not take place.
One-time access possible using the ixalo pro-
gramming device (5971).
Battery discharged or defective
→ 100 ms signal up and down, 1 s pause
Pairing mode active
→ 30 s slow beeping
*In this state, only transponders with unlimited access rights are granted access.
EN
Cylinder
3x
5x
5x
1x
+ 1x
+ 2x
2x
2x
+ 2x
∞
x
0 s
10 s
t
0 s
20 s
t
t
11.2023 | Designed in Germany
10 s
20 s
30 s