EN
Error list:
Pruning shear beeper version
Nº
Description of malfunction
1
Reserve number for possible future errors
2
Current sensor error
3
Hardware current overload (possibly damage
to metal oxide semiconductor)
4
Trigger base plate error
5
Software current overload
6
Torque locked (engine cannot rotate)
7
Phase failure (thermal overload, broken wire,
worn contact or mechanical failure)
8
Undervoltage / overvoltage
9
Voltage detection error
Pruning shear version with indicator display
Nº
Description of malfunction
1
Software current overload
2
Voltage detection error
3
Current sensor error
4
Torque locked (motor cannot rotate)
5
Lack of voltage
6
Voltage overload
7
Hardware current overload
8
Low battery
9
Phase failure (thermal overload, broken wire,
worn contact or mechanical failure)
10
Basic version: error in the trigger base plate.
Anti-cutting version: anti-cutting process
activated
11
Main board overheating
Beep times
Pending reservation
2
3
4
5
No beep, it will automatically
activate the protection
program
6
No beep, it will automatically
activate the protection
program
7
8
10
On-screen display
E7
E4
E3
E1
E5
E6
E2
E9
E8
E11
E15/16
9
Remarks
Reserved for possible future errors
The beep will continue at intervals and stop after
repeating 10 times
Remarks
The error code will disappear after recovering from the
malfunction
Error code will not disappear due to unrecoverable
errors
Error code will not disappear due to unrecoverable
errors
The error code will disappear after recovering from the
malfunction
The error code will disappear after recovering from the
malfunction
The error code will disappear after recovering from the
malfunction
Error code will not disappear due to unrecoverable
errors
Error code will not disappear due to unrecoverable
errors
Error code will not disappear due to unrecoverable
errors
The error code will disappear after recovering from the
malfunction
El código de error desaparecerá después de recuperar-
se del mal funcionamiento