Installation Instructions – IFLD Infrastructure Flood
7 .
To change luminaire tilt angle, loosen (2) adjusting bolts,
rotate fixture to the desired angle, and tighten the (2)
adjusting bolts to 23 ft lbs. The fixture can be adjusted
from -10 degrees to 80 degrees from horizontal for pole
mount configuration.
8.
Reinstall the cover plate with gasket onto the pole side
arm with (3) 8-32 screws.
Figure 6.
Pendant Mounting (Figure 7, 8, 9)
Surface mount
Tools Required:
Ratchet, 1-1/8" and 9/16˝ socket, Torque
wrench (ft-lbs) and #2 Phillips screwdriver.
1.
Mount luminaire to a surface ensuring maximum
contact across the bottom surface of the pendant. Use
hole pattern provided in Figure 8 to properly align the
pendant with center hole and 2x .45 holes with spacing
of 2.90 inches (Fig 7).
Mounting hardware recommended (supplied by
N
ote:
others); if mounting outdoor, all hardware must have
proper outdoor corrosion-resistant coating (Hot -Dip
Galvanized or equavalent):
a.
(2) 3/8-16 bolts (long enough to go through the
pendant and mounting structure) with (2) 3/8 -16
nuts. Torque to 25 ft lbs after horizontally aiming
the luminaire.
b.
(1) 3/4 bolt with flat washer thru center bolt (long
enough to go through the yoke and mounting
structure) and (1) 3/4 nut. Torque to 80 ft lb.
2.
Loosen but do not remove the (2) center bolts (Fig 1).
3.
Rotate Luminaire to desired aiming position and tighten
center bolts to 40 ft-lbs (Fig 7).
4.
Refer to wiring diagrams for power connection (Fig 3).
4
Cooper Lighting Solutions
IB506022EN
Installation instructions
Conduit mount
1.
Feed the supply wire through threaded end of pendant
(not supplied)
2.
Thread the first conduit nut (not supplied) onto the end
of the threaded conduit. Place the conduit through the
circular opening of pendant luminaire bracket (Fig 9).
3.
Secure the pendant to bracket by threading the second
conduit nut (not provided) underneath the bracket.
4.
Tighten both nuts securely.
5.
Loosen but do not remove the (2) ½-13 center bolts of
luminaire (Fig 7).
6.
Rotate Luminaire to desired aiming position and tighten
center bolts to 40 ft-lbs (Fig 7).
7 .
Refer to wiring diagrams for power connection (Fig 3).
Figure 7.
Ø1.050
(26.67)
Figure 8.
2X Ø.469
(11.91)
2X 1.45