5.
Inside the slip fitter arm, connect supply wires to
appropriate fixture leads:
a.
Supply side ground wire to green fixture lead.
b.
Supply side neutral wire to white fixture lead.
c.
Supply side line voltage wire to black fixture lead.
6.
Loosen the (2) 3/8-16 located in the slots to make angle
adjustments to the fixture. After angle adjustments
have been made, torque to 23 ft-lbs. The fixture can
be adjusted from -10 degrees to 80 degrees from
horizontal for pole mount configuration.
N
ote:
For ground mount option, fixture can be adjusted
from 0 degree to maximum of 65 degrees from
vertical. Do not exceed maximum angle specified
and only use factory-built ground mount option on
ground.
7 .
Replace the access cover to the arm. Tighten the (3)
#8 screws and torque to ~12 to 14 in-lbs
Figure 4.
Installation Instructions – IFLD Infrastructure Flood
Figure 5.
Pole Mounting (Figure 6)
Tools Required:
and #2 Phillips screwdriver.
1.
Loosen (3) #8 screws to remove access cover from
the arm and carefully set aside the cover plate and the
screws.
2.
If installing to round pole, use round pole adapter
provided at this point. If mounting to square pole
disregard the round pole adapter. Make sure round pole
adapter draft matches the back side of the arm properly.
Ensure the pole is drilled for a "N" pattern. A
N
ote:
template may be provided as required
3.
Remove pole top cap and place aside.
4.
Install and hold provided nut plate inside the pole. With
fixture supported, align (2) ½-13 fasteners through the
arm, pole adapter if used and hole pattern in the pole
into the nut plate. Hand tighten to ensure fixture is
aligned prior to tightening.
5.
Tighten both flange bolts within the fixture to 40 ft-lbs.,
while making sure pole side arm is level to the pole.
6.
While using cable clamp provided in the nut plate to
dress the wires as needed inside the pole, connect the
supply wires to appropriate luminaire leads (Fig 3).
a.
Supply side ground wire to green fixture lead.
b.
Supply side neutral wire to white fixture lead.
c.
Supply side line voltage wire to black fixture lead.
Cooper Lighting Solutions
Ratchet, 3/4˝ socket, Torque wrench (ft-lbs)
IB506022EN