Voltage
protection mode
The low voltage protection value is around 160V. If the voltage
of the power supply is lower, the device will automatically stop
working. The display will show the temperature indicators blinking.
When the voltage exceeds the 170V, the hair dryer will work again.
The high voltage protection value is around 260V. If the voltage
of the power supply is higher, the device will automatically stop
working. The display will show the temperature indicators blinking.
When the voltage is under 250V, the hair dryer will work again.
Except for the high and low voltage protection modes, the error
codes will disappear after three seconds. When the device is in
normal condition, it will automatically start working again.
12
Error detection
PROBLEM
POSSIBLE ORIG IN
During the operation air sometimes comes
The plug might be loosened. The air output might be
out and sometimes it does not.
blocked by some hair or the hands themselves.
The ON/OFF switch does not work.
ON/OFF switch fault. Internal component is damaged.
The display does not work properly or
Circuit board fault.
remains off.
The power cord is damaged.
The plug or the power cord are overheated.
Internal component is damaged.
Internal component is damaged.
Air does not come out when the device is
on and the hair dryer is very hot.
External object that blocks the air inlet.
Noise and vibration.
Internal component is damaged.
Product deformation.
Internal component is damaged.
Burnt-smelling during its use (except for
Internal component is damaged.
the first time).
In case of facing any other problem not mentioned above, please contact the after-sales department.
POSSIBLE SOLUTION
Properly plug the hair dryer. Do not block the air inlet.
Contact the after-sales department.
Contact the after-sales department.
Stop using the device immediately. Contact the after-
sales department.
Contact the after-sales department.
Contact the after-sales department.
Make sure that the air inlet is not blocked and use the
hair dryer once it is cool again.
Contact the after-sales department.
Contact the after-sales department.
Contact the after-sales department.
13