JBM 52382 Manual De Instrucciones página 6

Pinza amperimétrica
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
Value < 220V, phase "a" is missed
350V > Value > 260V, phase "b" is missed
When value is about 380V, disconnecte phase "a".
If symbol
does not appear, phase "c" is missing.
ZERO FUNCTION
In direct current, use ZERO switch to select/deselect relative measurement method.
MAINTENANCE
BATTERY REPLACEMENT
If the signal
appears on the display, it indicates battery should be replaced. Remove screws and replace batteries with new ones
(size AAA batteries).
TECHNICAL SPECIFICATIONS
Specifictions shown below are based in temperatura range 23°C ± 5°C and relative humidity <75%. Accuracy: ([% value] + [number
of significant digits), is guaranteed for one year.
CURRENT MEASUREMENT
REF. 52382
Range
Resolution
AC 20A
10mA
AC 200A
100mA
AC 600A
1A
VOLTAGE MEASUREMENT
REF. 52382
Range
Resolution
DC 600V
1V
AC 600V
1V
Input impedance: ≥ 10MΩ
RESISTANCE
REF. 52382
Range
Resolution
2MΩ
1KΩ
Overload protection: 250V DC/AC
PHASE DETECTION
Range
Resolution
AC380V ± 10%
OK/Reversal/MISS
FR
GUIDE D'UTILISATION
SPÉCIFICATIONS GÉNÉRALES
Chiffres
Mesure
DCV
ACV
DCA
ACA
Résistance Ω
REF. 52952
Accuracy
± (2,5% + 10d)
REF. 52952
Accuracy
± (1,0% + 3d)
± (1,2% + 5d)
Input impedance: ≥ 10MΩ
REF. 52952
Accuracy
± (1,0% + 4d)
Overload protection: 250V DC/AC
Accuracy
± 3%
REF. 52382
3 1/2
1999
600V
600V
20A, 200A, 600A
2KΩ, 200KΩ,2MΩ
Range
Resolution
Accuracy
DC 200A
200A
± (2,5% + 10d)
AC 200A
200A
Range
Resolution
Accuracy
DC 20V
10mV
± (0,8% + 3d)
DC 600V
1V
± (1,0% + 3d)
AC 660V
1V
± (1,2% + 5d)
Range
Resolution
Accuracy
2KΩ
± (1,0% + 4d)
200KΩ
100Ω
2MΩ
1KΩ
± (1,0% + 4d)
REF. 52952
3 1/2
1999
20V,600V
600V
200A
200A
2000Ω
· 6 ·
loading

Este manual también es adecuado para:

52952