FUNKTION BUTTON
¤
"
"
¤
Press "
" Button to switch on / off the backlight.
"mils/μm"
Press "mils/μm" Button switch from mils to μm.
(1 mils = 25.4 μm)
"CAL"
See section Calibration
OPERATION
Switch Unit On/Off
1. Press the trigger to activate the device and
wait until the symbol appears "run".
The device is now used.
2. Automatic Power Off (APO):
After 15 seconds, not in use, the device switches off automatically.
MEASUREMENT
1. Press the trigger to turn on the device.
2. Press the sensor firmly to the coated surface to be measured. Pull the trigger and allow him to
immediately release it. DO NOT PROBE OF THE UNDERGROUND before the measured value is
displayed.
3. If the measured coating are out of range, is still a measurement value is displayed. This is less
accurate than indicated in the specifications.
CALIBRATION
Tip: Take your time, the device is achieved in the calibration mode through step 6 or
press and hold for 4 seconds, the CAL button.
1. Select the desired unit before calibration (mils / mm). It can not be changed during the calibration.
2. During calibration, the automatic shutdown is inactive.
EASY CALIBRATION
1. For calibration, please take the calibration plate (round metal disc) and the calibration sheet
(rectangular sheet labeled 3.9 mils, 99μm) at hand.
2. Press the trigger to activate the device.
Press the "CAL" and then the ▼ button for 4 seconds to start the calibration.
The display flashes "- - 1".
3. Press the device with the probe on the calibration film (3.9 mils, 99μm), the calibration plate (round
metal plate) must be lie under the calibration film ,press and hold the trigger till the item shows a
reading.
4. The trigger can now released and the device can be removed from the calibration plate.
Use the ▼ ▲ button to set the displayed reading on the thickness of the calibration plate (3.9 mils
or 99μm).
5. Press "CAL" button to confirm the value. The display flickers "- - -" then "- - 2".
6. Then press again the "CAL" button and hold for 4 seconds to leave the calibration menu and to
return to the application mode.
SW-Stahl und Werkzeugvertriebs GmbH
L
e
v
e
k r
u
s
r e
t S
a r
s
s
e
6
5
D
4 -
2
8
9
7
R
e
m
s
c
h
e
d i
Tel. +49 (0) 2191 / 46438-0
F
ax +49 (0) 2191 / 46438-40
- E
M
a
: l i
n i
o f
@
s
w
s
a t
l h
d .
e