EGO PRO X PGX1400PB Traducción De Las Instrucciones Originales página 14

TROUBLESHOOTING
EN
AC Mode
PROBLEM
The hub status
indicator flashes
orange.
The hub status
indicator flashes red.
The hub status
indicator is solid red.
The battery-bay
status indicator
above one of the
batteries is solid red.
The hub-status
indicator is solid
green.
The power bank
AC status indicator
turns off.
The hub-status
indicator is solid
green.
14
56 VOLT PGX
CAUSE
The hub will charge slowly when
the hub temperature is 40 – 60 °C,
which is normal operation.
Hub output overcurrent.
The hub's fan is blocked or
damaged.
AC input under-voltage.
Hub is too hot.
Hub is too cold.
The battery pack is too hot or too
cold.
Bad connection between the hub
and power bank.
Faulty power bank.
POWER BANK — PGX1400PB
TM
SOLUTION
No action needed.
Reset the hub by unplugging the hub from power
supply and waiting until the hub-status indicator
turns off, then reconnect the plug to the power
supply. If this does not solve the problem, contact
your local EGO Service Center.
Unplug the hub, shake the hub slightly, and then
reconnect the hub to the power supply to see
whether the hub works normally. If it does not work,
contact your local EGO Service Center.
No action needed. The hub will resume to charge
after the AC input voltage is stable. If the AC input
voltage is still not stable after many attempts,
unplug the hub from power supply and wait until the
hub status indicator turns off, then reconnect the
plug to the power supply.
Unplug the hub from power supply and wait until
the hub cools down, then reconnect the plug to the
power supply. If this does not solve the problem,
contact your local EGO Service Center.
Allow the hub to warm up. Charging will resume
when the hub returns to the normal temperature.
Allow the battery pack to cool down or warm up.
Charging will begin when battery pack returns to the
normal temperature.
Try to disconnect the hub connector and reconnect
it to the power bank.
Contact your local EGO Service Center