Tennant IPC PW-E101 Manual De Instrucciones página 9

Cuadro de mandos - funciones de control
Ocultar thumbs Ver también para IPC PW-E101:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 19
when waiting, led flashing in "TSI" status.
Indicator light D): Active heating system. (Tempe-
rature adjustment "B" set > 20°C).
Indicator light E): Faults signals: Identified faults
are reported on the display. See possible faults.
Indicator light F): Descaler level; the light on and
related message on the Display, indicates low level.
Indicator light G): Detergent solution level; the li-
ght on and related message on the Display, indicates
low level.
Indicator light H): Temperature Readiness; if this
light turns-on on the display, it means that the preset
temperature has been achieved.
If the preset temperature is not achieved within 4
minutes of normal hot water functioning, the light fla-
shes rapidly. Regulate the regulating valve slightly to
reduce the water flow. This will allow the attainable of
the prest temperature.
If the preset temperature lowers while using the hot
water function, the light flashes slowly until it reaches
the desired temperature.
HIGH PRESSURE WASHER SHUTDOWN -
POSSIBLE FAULTS
1) High pressure washer not used for more than 20
min., high pressure washer in total stop mode (TSI).
This is signalled by indicator light C) and E) flashing
and related message on the Display.
2) 200h programmed maintenance interval expired.
The light will go off following maintenance by the au-
thorised service centre.
The fault is signalled by indicator light E) on steady
and related message on the Display.
3) Micro-leaks detected or water nozzle clogged: the
high pressure washer shuts down.
The fault is signalled by indicator light E) flashing
and related message on the Display.
4) No water: After 60 sec. of operation with no water
detected, the high pressure washer shuts down.
The fault is signalled by indicator light E) flashing
and related message on the Display.
5) Motor thermal protector activated: the high pres-
sure washer shuts down.
The fault is signalled by indicator light E) flashing
and related message on the Display.
6) High Temperature Fault: The burner shuts down.
The fault is signalled by indicator light E) flashing
and related message on the Display.
7) NTC Probe failure: the heating system stops.
The fault is signalled by indicator light E) flashing
and related message on the Display.
N.B. To reset the fault signals, turn main switch
"A" to pos."0" and then back to pos. "I".
For further assistance, contact the technical ser-
vice centre.
EN - english
7
loading