Bypass function
► If the Powerstation is connected to an AC power supply, devices connected to the Powerstation can take the power
supply directly from the AC power source without the power supply first having to pass through the Powerstation
battery.
UPS function
► The UPS (Uninterruptible Power Supply) function automatically switches the connected devices that are currently
using the bypass function over to using the Powerstation battery within 10 milliseconds if the AC power supply is
interrupted. This ensures a continuous power supply.
Charging via the mains (alternating current)
Charging with solar modules
► The PATONA Platinum Powerstation Autarc 1200 can be charged with solar modules.
► Make sure that the input voltage is between 12-48V. If the voltage is above 48V, the overvoltage protection is activa-
ted and the charging process is interrupted.
Caution:
► The effectiveness and efficiency of the charging process depend on various factors such as solar radiation, humidity
and other conditions.
► The solar module must not exceed a voltage of 48V.
► Ensure that the maximum output of the solar module does not exceed 500W.