Maxvac DV120-MBN Instrucciones De Uso Y Mantenimiento página 21

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 99
TROUBLESHOOTING
Problems
The appliance will
not start
Reduced
Efficiency
The RPM rate of the
motor is noticeably
higher.
DV120
Causes
No power
Defective power cord,
switches or motor.
Drum too full
Filter cartridge is dirty
or caked.
Clogged tube or
accessories.
Drum too full.
Filter cartridge is dirty
or caked.
Clogged tube or
accessories.
Drain tap (K) open
Solutions
Check that the power
socket is working
Contact your technical
service centre (see
attached list).
Empty Drum
Thoroughly clean or
change the filter,
Check the hose or
accessories.
Check the drum.
Thoroughly clean or
change the filter,
Check the hose or
accessories.
Close the drain tap (K)
MAX-VAC.COM