Emerson AVENTICS AF2 Instrucciones De Montaje página 23

Ocultar thumbs Ver también para AVENTICS AF2:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 46
Electrics
Table 15: Data for AS-AF2-Ethernet and HF-AF2-Ethernet variants
Supply voltage U
V
Protection class
Connection type
Power consumption
Table 16: Data for AS-AF2-IO-Link and HF-AF2-IO-Link variants
Supply voltage U
V
Protection class
Connection type
Output signal
Output load
Lower signal level
Upper signal level
Digital output
Power consumption
Signal voltage HIGH
Signal voltage LOW
Inductive load
Capacitive load
2)
All connections are protected against reverse polarity and are overcurrent-proof. Q1, Q2,
and Qa are short-circuit-resistant.
3)
Configuration of the digital output: PNP/NPN/push-pull.
Standards and directives complied with
Standard / directive Description
EMC directive
Electromagnetic compatibility of electric products and electronic
2014/30/EU
products
EN 61326-2-3
Electrical equipment for measurement, control, and laboratory use –
EMC requirements, Part 2-3: Particular requirements – test arrange-
ment, operating conditions, and performance characteristics for
transducers with integrated or remote signal conditioning
Pneumatics
Table 17: General data
Medium
Process temperature
Process pressure
Table 18: Data for AS-AF2 variant
Process connection
Table 19: Data for HF-AF2 variant
Process connection
14 Accessories
Information on accessories can be found on the product page in the Emerson
store.
Description
Connecting cable, CON-RD, M12x1 series
AVENTICS™ AF2 | R412026496–BAL–001–AC | English
Specifications
36 ... 57 V DC, Power over Ethernet acc. to
IEEE802.3af
III
M12x1 round plug, 8-pin X-coded
≤ 12 W
Specifications
2)
17 ... 30 V DC
III
M12x1 round plug, 5-pin A-coded
• 1x analog output 4 ... 20 mA or 1x digital
switch output / pulse, frequency output
configurable
• 1x analog output 4 ... 20 mA or 1x digital
3)
switch output (configurable)
4 ... 20 mA, 500 Ω, if U
> 15 V
V
3.5 ... 3.8 mA
20.5 ... 21.5 mA
≤ 100 mA per output
< 12 W (@ 24 V DC without output load)
> U
 ... 2 V
V
≤ 2 V
1 H
100 nF (2.5 nF in IO-Link mode)
Specifications
• Compressed air (air quality as per
ISO 8573-1:2010 [3:4:4])
• Argon, nitrogen, carbon dioxide
-20 ... +60 °C
0 ... 16 bar
Specifications
G3/8", G1/2", G1" (in accordance with
DIN ISO 228-1)
Specifications
• DN40: R1 ½ or 1 ½" NPT
• DN50: R2 or 2" NPT
Item no.
R412027647
23
loading