BURG-WACHTER Pure-Safe E Instrucciones De Uso página 4

Ocultar thumbs Ver también para Pure-Safe E:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 34
Instruction Manual
Diagram
Keypad
CLOSE
To lock the safe
Display
ENTER
Emergency Lock
Turn on the electronic lock and
confirm the entry of a code
Foreword
Dear customer,
Thank you for purchasing a safe from the Pure-Safe series
from BURG-WÄCHTER. This safe was manufactured to a high
standard using our latest in technological advancements.
The Pure-Safe series can be operated as a standard safe or
programmed into hotel mode. In addition, all safes have an
integrated mechanical emergency lock.
Important: Please read the entire instructionmanual
before you start programming the safe.
We hope you enjoy using your new Pure-Safe,
Your BURG-WÄCHTER KG
4 I Englsih
Important notes
Be sure to store your user codes and the emergency key in a secure
location and not inside the safe (the emergency lock is located to the
right of the keypad)
Don't use simple codes that are easy to guess (e.g. 1-2-3-4-5-6)
For security reasons we recommend you do not use personal numbers
such as your date of birth or telephone number as a code to operate
the safe
If the safe is not going to be used for a prolonged period of time,
please remove the batteries
The factory set admin code and default user code must be changed to
your own unique code to ensure the safe is secure
The safe only achieves its intended protection after it is anchored in
place to a solid part of a building such as a wall or floor. Please use the
pre-drilled anchoring points (in the base and back wall of the safe)
fixings to secure the safe in place
Please contact your retailer if you have any questions or technical issues
General
An admin code and user code are available to operate the safe, plus the
addition of up to 5 programmable fingerprints.
The admin code must have 8-digits.
The user code can be between 3 to 6-digits.
Admin code: 1-2-3-4-5-6-7-8 (factory set default)
User code: 1-6-8 (factory set default)
Technical specification
Blocking Times:
After 3x wrong code entries: 5 minutes
Battery Specification:
4x AA MIGNON LR6 ALKALINE
Specified operating
-15 °C to + 50 °C
conditions
up to 95% rel. humidity
(non-condensing)
Signal tones
1 x beep
Key entry registered
2x beeps
Input correct / accepted
3x beeps
Input wrong / denied
Installation
Remove the enclosed emergency keys from the packaging.
Use the emergency key to open the safe door (see diagram for location).
Remove the plastic strip located by the battery compartment on the
inside of the door to activate the batteries.
With the door still open, turn the emergency key and remove it from
the emergency lock hole.
Press the ENTER button.
Enter the user code (factory default code: 1-6-8) and confirm by
pressing the ENTER button.
The safe can now be programmed to your own admin and user code.
Chapter 1: Operation with a code
Opening the safe with the user code
Press the ENTER button
Enter the 3 to 6-digit user code (factory default code: 1-6-8) and confirm
with ENTER button. You will hear 2 short beeps.
The door will open automatically.
If you hear 3 short beeps, an incorrect code has been entered. Please try again.
Closing & locking the safe
Push and hold the door of the safe in the closed position. Press the CLOSE
button to automatically extend the bolts and lock the safe.
Note: If something is blocking the door during the locking procedure, the
display will show"BLOCK" to indicate the safe cannot be locked. Please remove
the obstruction and try again.