Utilitech 7131-04 Manual Del Usuario página 13

Ventilador con sensor de humedad
Idiomas disponibles

Idiomas disponibles

TROUBLESHOOTING
PROBLEM
The fan seems louder
than it should be.
The fan has an abnormal
sound or vibration.
The fan is not clearing
humidity from the room.
The fan keeps running
even though the humidity
level is lower than the
user-adjustable set-point
for the relative humidity.
NOTE: The humidity
sensor tolerance is +/-
10% RH.
LIMITED 5-YEAR WARRANTY
If this product fails due to a defect in materials or workmanship at any time during the first FIVE years of ownership, the
manufacturer will replace it free of charge, postage-paid at their option. This warranty does not cover products that have
been abused, altered, damaged, misused, cut or worn. This warranty does not cover use in commercial applications. Use
only manufacturer-supplied genuine warranty repair replacement parts to repair this fan. Use of non-genuine repair parts
will void your warranty. The manufacturer DISCLAIMS all other implied or express warranties including all warranties of
merchantability and/or fitness for a particular purpose. As some states do not allow exclusions or limitations on an implied
warranty, the above exclusions and limitations may not apply. This warranty gives you specific legal rights, and you may
have other rights that vary from state to state.
This warranty is limited to the replacement of defective parts only. Labor charges and/or damage incurred during installation,
repair, replacement as well as incidental and consequential damages connected with the above are excluded. Any damage
to this product as a result of neglect, misuse, accident, imporper installation or use other than the purpose SHALL VOID
THIS WARRANTY.
Shipping costs for return product as part of a claim on the warranty must be paid for by the customer.
Inquiries regarding warranty claims can be directed to 866-994-4148, 8 a.m. - 8 p.m., EST, Monday - Sunday. You could also
contact us at [email protected].
POSSIBLE CAUSE
The CFM is too great for the space.
The damper is damaged or not working
properly.
The bend in the duct is too close to the
fan discharge.
The fan discharge is reduced to fit a
smaller duct.
The fan body is not attached securely.
The fan body is not attached securely.
The grille is not attached securely.
The circular duct is not secured to the
duct connector.
There is insufficient airflow intake in the
room.
There is insufficient CFM.
NOTE: Using a tissue is not the
correct method for determining if the
fan is operating properly. If the fan
clears steam from the room within
approximately 15 minutes of completing
your shower, then the fan is operating
properly.
Outdoor humidity is back drafting into
the fan.
The fan is operating in manual mode.
Be sure the CFM rating on the fan matches the
square footage of your room.
Check the damper to ensure it is opening and
closing properly. If the damper has become
damaged, please call Customer Service.
Be sure you do not have any sharp bends in the duct
within 18 in. of the fan discharge.
Use the recommended size ducting to reduce fan
noise.
Be sure the fan is securely attached to the ceiling
joists.
Be sure the fan housing is securely attached to the
ceiling joists or wall studs.
Be sure the grille is pushed upward gently until it is
firmly attached to the fan housing.
Be sure the duct tape or clamp is secured for an
airtight connection.
Be sure a door or window is slightly ajar or open to
allow airflow. The fan is not able to draw air out of
the room without enough airflow.
Be sure the CFM rating on the fan matches the
square footage of your room.
Continue to let fan run since it is good to keep
venting the house and the electric cost is minimal
(estimated at less than $10 per year).
Verify the humidity sensing function has been
selected. The LED indicator light in the grille will
be blue when humidity sensing mode is turned on.
13
SOLUTION
Printed in China
loading

Este manual también es adecuado para:

5632649