OPERATION
CAUTION: DO NOT THROW ITEMS INTO THE STORAGE AREA. FAILURE TO HEED THESE
RECOMMENDATIONS COULD RESULT IN DAMAGE TO THE INTERIOR OF THE
CABINET.
REFRIGERATORS
The factory setting for temperature range is 34°F - 38°F.
CONTROL PANEL SOLID-STATE THERMOSTAT
FRONT PANEL COMMANDS
SET
SET: To display target set point; in programming mode it selects a
parameter or confirm an operation..
DEF: To start a manual defrost
UP: To see the last temperature alarm happened; in programming mode it
browses the parameter codes or increases the display value
DOWN: To see the last temperature alarm happened; in programming
mode it browses the parameter codes or decreases the display value
Key Combination:
To lock & unlock the keyboard
To enter in programming mode
To return to the room temperature display
LED
MODE
On
Compressor enabled
Flashing
Anti short cycle delay enabled (AC parameter)
On
Defrost enabled
Flashing
Dripping in progress
On
Measurement unit
Flashing
Programming mode
On
Measurement unit
Flashing
Programming mode
MAIN FUNCTIONS
1. How to See the Setpoint
1. Push and immediately release the SET key: the display will show the set
point value.
2. Push and immediately release the SET key or wait for 5 seconds to display
the sensor value again.
3
BEER DISPENSERS
FUNCTION
2. How to Change the Setpoint
1. Hold the SET key for more than 2 seconds to change the set point value.
2. The value of the set point will be displayed and the
3. To change the set value, push the
4. To set new point value, push the SET key again or wait 10 seconds.
3. How to Start a Manual Defrost
1. Hold the
key for more than 2 seconds and a manual defrost will start.
4. How to Lock the Keyboard
1. Hold the
and
keys for more than 3 seconds.
2. The "POF" message will be displayed and the keyboard will be locked. At
this point, it will be possible only to see the set point or the MAX or MIN
temperature stored.
3. If a key is pressed for more than 3 seconds, the "POF" message will be
displayed.
5. How to Unlock the Keyboard
1. Hold the
and
keys together for more than 3 seconds, until the "POF"
message is displayed then press
program.
ALARM SIGNALS
How to See the Alarm and Reset the Recorded Alarm
1. Push the
or
key to display the alarm signals.
2. When the signal is displayed, hold the SET key until the "rst" message is
displayed. Push the SET key again. The "rst" message starts blinking and the
normal temperature will be displayed again.
MESSAGE
CAUSE
"P1"
Room probe failure
"P2"
Evaporator probe failure
"HA"
Maximum temperature alarm
"LA"
Minimum temperature alarm
"EA"
External alarm
"CA"
Serious external alarm
"dA"
Door Open
LED starts blinking.
or
key within 10 seconds.
or
key to select the item to check or
OUTPUTS
Compressor output according
to "Cy" and "Cn"
Defrost end is timed
(Only XR04CX)
Outputs unchanged
Outputs unchanged
Output unchanged
All outputs OFF
Compressor and fans restarts