4.1.4.11 Night Alarm (22h-9h)
When an alarm occurs, the unit stops its production and shows an acoustic and
visual alarm to indicate that it's necessary to correct the problem.
However, it is possible to keep the alarm silent between 10:00 pm and 9:00
am, selecting the option Night Alarm = N
4.1.5- Chlorine menu
With this menu you can select all parameters related to chlorine production.
4.1.5.1- Production of cl.
Configuration of the maximum production of chlorine.
From 0% to 100% Press "OK" and use the arrows to change the value.
Press "OK" to confirm the adjustment.
Note: Chlorine production may be limited regardless of the operation mode
(manual, automatic...) that is selected.
4.2.5.2- Adjustment of the set value (Max. ORP or Max. PPM)
ORP Mode in which a Redox probe (OPTIONAL) is installed.
In this case, adjust the oxidation potential to the required level. For private
swimming pools that are not used frequently, 650 mV is a sufficient value 700
mV is the suitable value for the majority of swimming pools. Press "OK" to
confirm the adjustment. However, the best way to adjust the optimal ORP value
is to analyze the water and determine the ratio between ORP and PPM, because
there are some differences between several types of water.
NOTE: if working in automatic, you can also adjust the production percentage
from 0% to 100%,
PPM Mode
in which a free chlorine probe (OPTIONAL) is installed.