Valve Body
Coupling
Inlet
Nut
Ferrule or
Flared End
Supply
Tube
Coupling
Supply
Nut
Tube
Ferrule
Supply
Stop
8. Supply Connections
Connect the supply tubes to the valve inlets and supply stops.
(Left is hot - right is cold.)
Wrench-tighten all connections.
9. Installation Checkout
Connect the tailpiece and P-trap.
Ensure that all connections are tight.
Remove the aerator by turning it counterclockwise.
Turn on the main water supply and check for leaks. Repair as
needed.
Open both hot and cold valves and run water through the spout
for about a minute to remove debris. Check for leaks. Turn valves
off.
Remove any debris from aerator and reinstall.
116370-2-AB
Spout
Aerator
10
Kohler Co.