5.5. Input contacts
The device has two input contacts (CH1 ACTIVATION and
CH2 ACTIVATION) that allow to remotely activate or
deactivate each of the music channels.
The type of activation is configurable by pulse or by level
using the Call Point or Call Point Configurator software. If
configured by pulse, the detection time of the activation
pulse can be configured (0-50-100-200-200-300-400-500-
500-1000-1500-2000 milliseconds).
6. COMMISSIONING OF THE DEVICE
To commission the MI2-700ETH we must send configurations to it via an Ethernet connection. Accomplishing this requires a PC
equipped with a network card and connected to the MI2-700ETH through a switch or directly using a network cable. The PC must
have the configuration software installed.
1. Make the connections between the devices.
2. Turn on the power supply to the devices.
3. Use the Call Point or Call Point Configurator software to configure the parameters of the MI2-700ETH and send the settings to
the device.
ATTENTION. In order to be able to send configurations to the device, it is necessary that the device and the PC are
within the same IP address range. It is also necessary that the network addresses of the device and those set from the
configuration software match.
By default, the device's network configurations are as follows:
IP ADDRESS:
NETMASK:
GATETEWAY: 0.0.0.0 (without Gateway)
If you wish to assign a different network address to the unit than the default one, follow the next section 6.1
Configuration of the MI2-700ETH network addresses.
MI2-700ETH 5.2.002 version
MI2-700ETH
10.1.1.1.1
255.0.0.0
Converter of 2 analogue audio signals
Figure 10
CHANNEL 2
ACTIVATION
CHANNEL 1
ACTIVATION
to 2 channels of streaming via IP
R+D Department
10