3. REAR VIEW
1) Power supply input 100-240Vac 50/60 Hz. It allows the
connection of the device to the mains by means of the
supplied cable (CEE7 Male / C13 Female, 1.8m).
2) Mains power fuse (1A). There is a spare fuse inside the
same box.
3) Grounding.
4) RESET button. Clears the settings and restores the default
network address:
IP ADDRESS: 10.1.1.1.1
NETMASK: 255.0.0.0.0
GATETEWAY: 0.0.0.0.0 (no Gateway)
To do this, press and hold it for 10 seconds with the unit
turned on (the front STREAMING indicators will blink 4
times at the end of the process).
5) CONSOLE connector. Mini USB connector. Allows to
monitor the system. Specialized personnel only.
6) ETH A connector. Used to connect the device to the IP
network.
(6a) LINK indicator (yellow LED):
Indicates connection to the network.
(6b) ACTIVITY indicator (green LED):
Flashing indicates sending or receiving data.
7) ETH B connector. Used, in a redundant network, as a
secondary connection to the IP network.
MO2-700ETH 5.2.02 Version
MO2-700ETH
Figure 2
8) PAGING/MUSIC connector. Audio output of the paging
channel.
By setting DIP switch 1 to ON, this paging output also
becomes the music channel output, so that it emits the
music channel while no paging is received. For its
connection see section 5.4.
9) MUSIC connector. Audio output of the music channel. For
its connection see section 5.4.
10) Configuration DIP switch.
DIP switch 1 PAG-MUS
In OFF position, the PAGING/MUSIC connector is used
only as paging output (PAGING).
In ON position, the PAGING/MUSIC connector is used
as paging and music output.
DIP switch 2 COM-GND
Connects (ON position) or separates (OFF position) the
COM contact of the terminal strip to the GND of the
device.
11) Output contacts. For their connection follow section 5.6.
COM. Common.
MUS OUT CTRL. It is activated when the music channel
is active.
PAG OUT CTRL. Activated when the paging channel is
active.