6. COMMISSIONING OF THE DEVICE
To commission the CC-200ETH8 we must send configurations to it via an Ethernet connection. Accomplishing this requires a PC
equipped with a network card and connected to the CC-200ETH8 through a switch or directly using a network cable. The PC must
have the configuration software installed.
1. Make the connections between the devices.
2. Turn on the power supply to the devices.
3. Use the PA Manager software to configure the parameters of the CC-200ETH8 and send the settings to the device.
ATTENTION. In order to be able to send configurations to the device, it is necessary that the device and the PC are
within the same IP address range. It is also necessary that the network addresses of the device and those set from the
configuration software match.
By default, the device's network configurations are as follows:
IP ADDRESS:
NETMASK:
GATETEWAY: 0.0.0.0 (without Gateway)
If you wish to assign a different network address to the unit than the default one, follow the next section 6.1
Configuration of the CC-200ETH8 network addresses.
6.1. Configuration of the CC-200ETH8 network addresses
To change the default network settings of the MI2-700ETH do the following:
1. From the PC, open a browser, enter the IP address of the unit and press ENTER.
By default, the IP address is 10.1.1.1: The IP address range of the device and
those of the PC must match. If this is not the case, you must first change the
network settings of the PC to bring it within the range of the device (e.g., the PC
could have the IP address 10.1.100.152).
2. Enter the user name optimax, the password 1933 and click on the Login button.
CC-200ETH8 Version 6.0.001
CC-200ETH8
10.1.1.1.1
255.0.0.0
TCP/IP connections controller
for Optimax2 system
R+D Department
10