Tennant IPC PW-H61 Manual De Instrucciones página 30

Hidrolimpiadora por agua caliente
Ocultar thumbs Ver también para IPC PW-H61:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 73
A
FIG. 12
tal crushing.
- Do not use the machine if the supply cable is da-
maged.
- The use of any electric appliance requires the re-
spect of some basic rules:
• Do not touch the appliance with wet or damp hands
or feet.
• Do not use the appliance bare-footed or with unsu-
itable clothing.
• Do not pull the supply cable or the appliance itself
in order to disconnect the plug from the electric sup-
ply.
(For water cleaners rated at less than 3 kW fitted
with plug).
As for the protection against electric shock, the
H.P.cleaner belongs to CLASS I.
Failure to observe the above warning frees the
manufacturer from all responsibility and consti-
tutes negligent use of the product.
USING THE CLEANER
CONTROL PANEL
A - On/off switch
B - Temperature regulator
C - Pressure gauge.
STARTING THE CLEANER
1) Turn on the water supply tap (fig. 10A).
2) Connect the water cleaner to the mains electricity
supply by plugging the plug into the socket.
3) Start the cleaner by turning the selector switch to
pos. "I" (fig. 12A).
Warning
The high pressure water jet generates a reaction for-
ce in the lance. Keep a firm grip on the lance handle.
4) Press the trigger on the gun and begin washing.
5) For operation of the pressure washer with hot wa-
ter, refer to the "Control Panel" booklet.
28
OK
ECO
B
C
EN - english
FIG. 13
Warning
In water cleaners with the "Total Stop" system, the
motor starts and stops when the lever on the lance
handle is actioned or released.
Danger
Do not block the handle lever in the delivery position.
IMPORTANT!
To eliminate any impurities or air bubbles from the
water circuit we advise starting the cleaner for the
first time without the lance and letting the water run
out for a few seconds.
Impurities could block the nozzle and cause malfun-
ction (fig. 13).
Warning
N.B. To reset the indicators, rotate the main swi-
tch "A" (fig. 12) to the "O" position and then to
the "I" position. Refer to the "Control Panel".
IMPORTANT:
For maintenance and/or repairs, use only ori-
ginal spare parts which offer the greatest cha-
racteristics of quality and reliability. Failure to
use original spare parts frees the manufactu-
rer from all responsibility.
USING THE ACCESSORIES.
The high pressure washer has a nozzle with a flat
angle jet for cleaning large surfaces.
ROTARY HEAD (optional accessory)
The high pressure washer can be fitted with a head
with rotary nozzle to clean the most stubborn dirt.
Danger:
Aim the jet from a certain distance to avoid damage
caused by the high pressure.
Do not aim the jet at people, animals or electrical
sockets.
loading

Este manual también es adecuado para:

D1517p4 tD1719p4 tD1813p4 tD1915p4 tD2017p4 t