5.2 Replacing the power supply
unit
If you replace the power supply unit,
only use the original power supply unit
from the manufacturer (article number
0020292010 or 0020292011).
6 Decommissioning
1.
Deactivate the product in the myVAIL-
LANT app.
2.
Reset the product to its factory set-
tings by pressing and holding the but-
ton next to the LED for at least 10
seconds.
The LED goes out as soon as the
resetting process starts.
Your information and settings are
deleted.
The connection to the coupled ra-
dio room thermostat is deleted.
3.
Decommission the product.
7 Customer service
The contact details for our customer ser-
vice are provided on the back page, in the
appendix or on our website.
No software is perfect and, for that reason,
we are always working on additional im-
provements for you. If you find indications
of a weak spot or of a safety issue, please
notify us by sending a message to:
8 Product data
in accordance with EU
Ordinance no. 811/2013,
812/2013
Depending on the system configuration,
this product can work as a weather-com-
pensated control with room temperature
modulation and therefore contains the cor-
rection factor for control technology class
8000023372_00 Installation instructions
VI. A deviation from the seasonal room-
heating efficiency is possible depending on
the system configuration.
Temperature control class
Contribution to the seasonal
room-heating energy effi-
ciency ɳs
9 Technical data
Technical data – Wi-Fi gateway
Rated voltage
Requirement for the
power supply *
Average power con-
sumption
WLAN radio frequency
band
WLAN radio frequency
output (max. e.r.p.)
WLAN channels
WLAN encryption
IP assignment
Maximum environ-
mental temperature
Extra low-voltage wire
(bus line) – cross-sec-
tion
Height
Width
Depth
IP rating
Protection class
Permitted degree of
environmental pollution
* Applies for use with the connection cable
for the direct connection to the heat gener-
ator.
Technical data – Plug-in power sup-
ply unit
Rated voltage
Rated current
Output AC voltage
VI
4.0 %
5 to 24 V
ES1 or PS1 in
accordance with
IEC 62368-1
3 W
2.4 GHz
17.5 dBm
1 – 13
WPA2-PSK,
WPA3 personal
DHCP
50 ℃
≥ 0.75 mm²
96 mm
122 mm
36 mm
IP 21
III
2
120 to 230 V
AC
0.3 A
5 V
25