Wasserwerk WK7 Manual página 15

Con rociador extensible para vajilla
10955015-01_MA-WK7_SPGB_1222.indd 15
10955015-01_MA-WK7_SPGB_1222.indd 15
REPLACING THE CARTRIDGE
• Turn off the water supply.
• Remove the hot/cold badge .
• Undo the screw  in the lever 
Max.
using an Allen wrench.
• Pull off the lever .
• Remove the attachment ring .
• Remove the cartridge ring 
using a wrench.
• Remove the cartridge  and
replace it.
• Subsequently put the individual
Med.
parts together again.
Min.
 
15