INSTALLATION MEASURES
To carry out a proper installation of the operator parts as well
as to ensure the best automation performance, the
measurement levels shown in the following table shall be
complied with. Change the gate structure to adapt it to one of
the cases in the table, if necessary.
WARNING: In the case of leaf longer than 2 metres, an
electric lock must be fitted to ensure an efficent closig.
W [mm]
α
930
95°
930
120°
W [mm]
α
1130
95°
1130
120°
W [mm]
α
1540
95°
1540
120°
10
MOOV-B300
X [mm]
Y [mm]
140
140
160
120
MOOV-B400
X [mm]
Y [mm]
145
145
170
110
MOOV-B600
X [mm]
Y [mm]
280
280
310
120
Z [mm]
370
370
Z [mm]
470
470
Z [mm]
670
670